低温甲醇洗系统净化气CO_(2)含量超标的原因排查与处理

Cause investigation and treatment of CO_(2) exceeding in purification gas of low temperature methanol system
下载PDF
导出
摘要 鄂尔多斯市西北能源化工有限责任公司合成气净化系统中,出CO_(2)吸收塔的净化气量逐步上升并于2 h后超标,同时引起低温甲醇洗装置净化气中CO_(2)含量超标;分析了CO_(2)含量超标的原因,并对CO_(2)含量超标过程中导致生产运行指标异常的原因进行逐一排查,最终判定为贫甲醇冷却器绕管换热器泄漏造成的。详细分析了其泄漏原因,并提出了相应的处理措施,解决了低温甲醇洗装置净化气中CO_(2)含量超标的问题,同时采取了预防措施。 In the Ordos city northwest energy chemical limited liability company syngas purification system,the amount of purified gas in the CO_(2) absorption tower(C-2201)gradually increased and exceeded the standard after 2 hours.At the same time,it causes the CO_(2) in the purified gas of the low temperature methanol washing system to exceed the standard.To analyze the reason of CO_(2) exceeding the standard,and the abnormal phenomena of production operation index in the process of CO_(2) exceeding the standard are checked and analyzed one by one.The final judgment is caused by the leakage of E2209 spiral-wound heat exchanger.The causes of E2209 leakage are analyzed in detail,and the corresponding treatment measures are put forward.The problem of over-standard the CO_(2) in the purified gas of the low temperature methanol washing system was solved,and the preventive measures were taken.
作者 余顺 YU Shun(Ordos City Northwest Energy Chemical Limited Liability Company,Erdos,Inner Mongolia 010321,China)
出处 《煤炭加工与综合利用》 CAS 2022年第5期80-82,89,共4页 Coal Processing & Comprehensive Utilization
关键词 低温甲醇洗 换热器 泄漏 原因分析 low temperature methanol washing heat exchanger leakage cause analysis