摘要
减少电能损耗,建设低碳高效的智能电网已经是目前亟待解决的问题。因此,本文从福建电网公司开展的相关工作为依托,介绍了所执行的配电网精益运维管理措施;接着从理论上定量分析了配变一次侧电压水平、配变挡位等电压质量改善措施和配电网电能损耗之间的关系;最后,用工作实际数据验证了本文理论分析的合理性。对电力部门做好降损及管理工作及助力“双碳”的实现具有重要的参考意义。
Due to environmental pressure and energy shortage, how to reduce power loss and build a low-carbon and efficient smart grid has become an urgent problem to be solved.Therefore, this paper introduces the lean operation and maintenance management measures of distribution network based on the relevant work carried out by Fujian Power Grid Company;Then, the relationship between voltage quality improvement measures such as primary side voltage level and gear of distribution transformer and power loss of distribution network is analyzed quantitatively in theory;Finally, the rationality of the theoretical analysis is verified by the actual working data.It has important reference significance for the power department to do a good job in loss reduction and management and help the achievement of carbon peak and neutrality goals.
作者
周怡冰
陈芳
陈晶腾
高漩
刘必杰
ZHOU Yi-bing;CHEN Fang;CHEN Jing-teng;GAO Xuan;LIU Bi-jie(Putian Power Supply Company of State Grid Fujian Electric Power Co.Ltd.,Putian 351100,China;College of Electrical Engineering and Automation,Fuzhou University,Fuzhou 350108,China)
出处
《电气开关》
2022年第3期20-24,共5页
Electric Switchgear
关键词
电能损耗
电压偏差
技术降损
power loss
voltage deviation
loss reduction