超声波流量计在热工试验中的应用研究 被引量:3

Applied Research of Ultrasonic Flow Meter in Experiment
原文传递
导出
摘要 超声波流量计因为其准确度高、维护成本低等优势在流量测量中广泛应用。但在使用过程中,由于管道条件和安装过程的不确定性,以及测量介质的温度压力等状态参数发生变化,都增大了流量测量误差。基于热工水力试验应用需求,提出了一种提高超声波流量计测量准确度的方法,并阐述了超声波流量计时差法的工作原理、现场校准方法和结果,最后进行了不确定评定。 Ultrasonic flow meters are widely used in flow measurement because of high accuracy and low maintenance cost.The practical application of ultrasonic flow meter,the uncertainly of pipeline conditions and installation.as well as the change of parameters such as temperature or pressure of measuring medium will reduce the flow precision.A method which can improve the measurement accuracy of ultrasonic flow meter based on the experiment is presented.The principle,calibration and uncertainty evaluation are described.
作者 王艳芝 曹志泉 吴瑾 WANG Yanzhi;CAO Zhiquan;WU Jin(China Nuclear Power Operation Technology Corporation,LTD.Wuhan 430223,China)
出处 《自动化与仪器仪表》 2022年第6期239-241,共3页 Automation & Instrumentation
关键词 超声波流量计 时差法 现场标定 不确定度 ultrasonic flow meter time difference method On-line calibration uncertainty Evaluation
  • 相关文献

参考文献8

二级参考文献47

  • 1曲直,何杰,孙秀平,张喜和.单模双折射光纤弯曲时弹光效应[J].吉林大学学报(理学版),2004,42(4):582-585. 被引量:2
  • 2张伟刚,涂勤昌,孙磊,开桂云,袁树忠,董孝义.光纤光栅传感器的理论、设计及应用的最新进展[J].物理学进展,2004,24(4):398-423. 被引量:33
  • 3Albert Boggess,Francis J.Narcowich,小波与傅里叶分析基础[M].芮国胜,康健译.北京:电子工业出版社,2004.
  • 4IECA-1, International Code for the Field Acceptance Test of Hydrau- lic Turbines.
  • 5ASME PTC 18 -2002( Revision of PTC18 -1992), Hydraulic Tur- bines Performance Test Codes.
  • 6Technical Guides-Speed of Sound in Pure Water, National Physical Laboratory, UK.
  • 7王明吉周,围.单声道超声流量计在双弯管流场中的适应性研究[J].计量技术,2007(10):6-8. 被引量:4
  • 8曹丽.气体超声流量检测的关键技术研究[D].清华大学.
  • 9高丽虹.超声波液位计、流量计中时间测量方法的研究[D].西安石油大学.
  • 10訚耀保.先进流体测试技术(超声波流量计与雷达液位计)和液压与气动基本理论[M].上海交通大学.

共引文献25

同被引文献25

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部