摘要 本文简要介绍了水轮发电机组轴瓦间隙不匀危害,并分析了目前轴瓦间隙监测的主要手段,对水轮发电机组轴瓦间隙不匀故障原理进行介绍,提出了水轮发电机组轴瓦间隙不匀故障模型。经过数据采集、数据处理,建立故障模型,基于故障模型进行数据计算分析,根据计算结果,及时发现水轮发电机组轴瓦间隙不匀故障,以指导设备运行,并通过设备实际故障案例举例说明该分析方法确实可行,且具有很好的推广意义。 This paper briefly introduces the harm of bearing clearance unevenness of hydro-generator units,analyzes the main means of bearing clearance monitoring at present,introduces the fault principle of bearing clearance unevenness of Hydro-generator units,and puts forward the fault model of bearing clearance unevenness of Hydro-generator units.After data acquisition and data processing,then establish the fault model.Based on the fault model,the data is calculated and analyzed.According to the calculation results,the uneven bearing clearance fault of hydro-generator units is found in time to guide the operation of the equipment.Through the actual fault case of the equipment,the analysis method is feasible and has good promotion significance.
作者 张兴明 郗发刚 邢志江 王江 杨昶宇 ZHANG Xingming;XI Fagang;XING Zhijiang;WANG Jiang;YANG Changyu(Huaneng Lancang River Hydropower Co.Ltd.,Kunming 650000,China)
出处 《水电与抽水蓄能》 2022年第4期78-82,86,共6页 Hydropower and Pumped Storage
关键词 轴瓦间隙 瓦温偏差 瓦温离散度 Bearing clearance Tile temperature deviation Tile temperature dispersion