摘要
采用FDS(fire dynamic simulation)数值模拟软件对地下污水处理厂典型区域(大空间及十字廊道)进行了火灾模拟研究。通过在不同位置设置不同火灾功率的火源,研究了烟气温度、烟气运动、烟气浓度、能见度等因素随时间的变化。分析了不同工况下火灾对人员逃生的影响,为地下污水处理厂典型空间的消防设计提供依据。
The FDS(fire dynamic simulation)numerical simulation software is used to simulate the fire in the typical areas(large spaces and cross corridors)of underground sewage treatment plants.By setting the fire source of different fire power in different locations,the change of flue gas temperature,flue gas movement,flue gas concentration,visibility and other factors with time is studied.The impact of fire on personnel escape under different working conditions is analysed,which provides a basis for the fire protection design of typical space of underground sewage treatment plants.
作者
黄晓莉
戴栋超
纪莎莎
Huang Xiaoli;Dai Dongchao;Ji Shasha(Shanghai Urban Construction Design&Research Institute(Group)Co.,Ltd.,Shanghai)
出处
《暖通空调》
2022年第9期21-28,共8页
Heating Ventilating & Air Conditioning
基金
上海市地下污水处理厂工程设计系列应用研究课题(编号:XK2018157B)。
关键词
地下污水处理厂
大空间
十字廊道
烟气模拟
人员逃生
消防设计
underground sewage treatment plant
large space
cross corridor
smoke simulation
personnel escape
fire protection design