摘要
检验机构在对某新装电梯项目监督检验资料审核时,发现该批次电梯型号的轿门门锁装置电气安全装置上的触点在轿门门锁锁钩脱离挡销时瞬间断开后再次出现持续接通的现象(常闭触点)。通过比较和分析两家型式试验机构检验结论、电梯有关标准及安全技术规范,对该型号轿门门锁装置设计功能实现提出了疑问,重点讨论了质疑之处,并对本次监督检验中发现的问题提出了整改意见。
In the review section of the supervision and inspection data of a newly installed elevator project, inspection institution found a phenomenon that the contact on the electrical safety device of the elevator car door lock device appeared to be continuously turned on after the car door lock lockhook was immediately disconnected(normally closed contact). By comparing and analyzing the type test conclusions of two-type-test institutions, relevant standards and regulations of elevators,this paper raises questions about the realization of design function of car door lock device, focuses on the doubts, and corrected rectification opinions are put forward about the problems of this supervisory inspection.
作者
毕陈帅
戴光宇
卞敬
Bi Chenshuai;Dai Guangyu;Bian Jing(Tianjin Institute of Special Equipment Inspection Technical Research,Tianjin 300192;Key Laboratory of Digital Twin Generic Technology in Special Equipment for State Market Regulation,Tianjin 300192)
出处
《西部特种设备》
2022年第3期12-16,29,共6页
Western Special Equipment
关键词
轿门门锁装置
型式试验
安全保护装置
设计功能
Door lock device of elevator car
Type test
Safety protection device
Design function