摘要 文章以南昌大学游泳馆为例,选取游泳馆的室内游泳区域侧窗面积与墙面积的窗墙比为变量,通过Ecotect采光分析软件模拟分析建筑采光及节能,得到南昌地区游泳馆的窗墙比在0.2以上即可以满足建筑采光设计标准规范,并提出当窗墙比在0.35~0.4之间才能获得最好的室内天然光照度。 Based on the natatorium of Nanchang University,the ratio of the side window area to the wall area of the indoor swimming area of the swimming pool is selected as the variable,through Eoctect daylighting analysis software simulation analysis of architectural lighting and energy conservation,Nanchang area natatorium window wall than in 0.2 above that can satisfy architectural lighting design standards,and put forward when the window-wall ratio was between 0.35~0.4 to obtain the best indoor natural light.
作者 陶文茹
出处 《建筑与文化》 2022年第10期49-51,共3页 Architecture & Culture
关键词 游泳馆建筑 采光系数 室内天然光照度 建筑采光设计标准 Ecotect软件 swimming pool building daylight factor interior daylight illuminance standard for the daylighting design of buildings Ecotect