期刊文献+

锁定钢板治疗肱骨近端骨折的疗效与年龄、Neer分型的相关性分析 被引量:4

Effect of locking plate in the treatment of proximal humeral fracture and the correlation with age and Neer type
下载PDF
导出
摘要 目的:研究锁定钢板治疗肱骨近端骨折的疗效及患者年龄、Neer分型与疗效指标(Constant-Murley肩关节功能评分、X线片参数)的相关性。方法:回顾性分析经肱骨近端解剖锁定钢板内固定治疗的80例肱骨近端骨折患者临床资料,随访1年,分析年龄、Neer分型与Constant-Murley肩关节功能评分及X线片参数的关系。结果:年龄>60岁组术后Constant-Murley肩关节功能评分、颈干角、内翻角、颈干角内翻复位率低于年龄≤60岁组,前者肱骨大结节至钢板顶点的距离更大(P<0.05);Neer分型优良组术后Constant-Murley肩关节功能评分、颈干角、内翻角高于可差组,前者肱骨大结节至钢板顶点的距离更小(P<0.05);年龄与Constant-Murley评分、肱骨大结节至钢板顶点的距离呈独立负相关,而术后Neer评分与颈干角、内翻角、Constant-Murley评分呈独立正相关(P<0.05)。结论:锁定钢板治疗肱骨近端骨折患者术后肩关节功能与X线片参数有明显相关性,具有一定的监测意义。 Objective:To study the effect of locking plate in the treatment of proximal humeral fracture,and the correlation of age and Neer type with therapeutic effect indicators(Constant-Murley shoulder function score and X-ray parameters).Methods:The clinical data of 80 patients with proximal humeral fractures who underwent internal fixation with anatomical locking plate were retrospectively analyzed.The patients were followed up for 1 year.The correlation of age and Neer type with Constant-Murley score and X-ray parameters was analyzed.Results:The Constant-Murley score,collodiaphyseal angle,varus inclination and reduction rate of collodiaphyseal angle varus in the>60 year-old group were lower/smaller than those in the≤60 year-old group.The distance from greater tubercle of the humerus to the apex of the plate was greater in the>60 year-old group(P<0.05).The Constant-Murley score,collodiaphyseal angle and varus inclination in the excellent and good Neer type group were larger than those in the common and poor Neer type group.The distance from greater tubercle of the humerus to the apex of the plate was smaller in the excellent and good group(P<0.05).Age was independently negatively correlated with Constant-Murley score and the distance from greater tubercle of the humerus to the apex of the plate,while postoperative Neer score was independently positively correlated with collodiaphyseal angle,varus inclination and Constant-Murley score(P<0.05).Conclusion:There is an obvious correlation between postoperative shoulder function and X-ray parameters in patients with proximal humeral fractures treated with anatomical locking plate,it has certain monitoring significance.
作者 赵晶晶 朱君涵 徐砜 康万年 郭二鹏 丁郑旺 常德海 ZHAO Jing-jing;ZHU Jun-han;XU Feng;KANG Wan-nian;GUO Er-peng;DING Zheng-wang;CHANG De-hai(Department of Orthopedics,No.943 Hospital,Joint Logistics Support Force of PLA,Wuwei 733000,Gansu,China;Department of Laboratory Pathology and Blood Transfusion,No.943 Hospital,Joint Logistics Support Force of PLA,Wuwei 733000,Gansu,China)
出处 《川北医学院学报》 CAS 2022年第12期1631-1634,共4页 Journal of North Sichuan Medical College
关键词 肱骨近端骨折 解剖锁定钢板 年龄 Neer分型 Constant-Murley肩关节功能评分 X线片 Proximal humeral fracture Anatomical locking plate Age Neer type Constant-Murley shoulder function score X-ray film
  • 相关文献

参考文献8

二级参考文献47

  • 1吴克俭,王晓宁,张建,汤俊君,朱颖波,付中国.肱骨近端骨折[J].中华肩肘外科电子杂志,2014,2(4):209-218. 被引量:20
  • 2张平,李健,张美超,程立明,赵卫东,高梁斌,梁海翔,潘永谦,吕玉明.胸腰段三维有限元模型的建立[J].广州医学院学报,2005,33(4):7-10. 被引量:3
  • 3Constant CR,Murley AH.A clinical method of functional assessm-ent of the shoulder[J].Clin Orthop Relat Res,1987,3(214):160-164
  • 4Boyle MJ,Youn SM,Frampton CM,et al.Functional outcom es of reverse shoulder arthroplasty compared with hemiarthroplasty for acute proximal humeral fractures[J].J Shoulder Elbow Surg,2012,6(3):1-5
  • 5Schtitz M, Maller M, Kaab M, et al. Less invasive stabilization system (LISS) in the treatment of distal femoral fractures [J]. Acta Chir Orthop Traumatol Cech, 2003, 70(2) ..74-82.
  • 6Florin M, Arzdorf M, Linke B, et al. Assessment of stiffness and strength of 4 different implants available for equine fracture treatment: a study on a 20 degrees oblique long-bone fracture model using a bone substitute[J]. Vet Surg, 2005, 34(3) : 231-238.
  • 7Stoffel K, Dieter U, Stachowiak G, et al. Biomechanical testing of the LCP-- how can stability in locked internal fixators be controlled?[J]. Injury, 2003, 34(Suppl 2) : B 11-19.
  • 8Nassiri M, Macdonald B, O' Byrne JM. Computational modelling of long bone fractures fixed with locking plates - How can the risk of implant failure be reduced?[J]. J Orthop, 2013, 10(1) : 29-37. DOh 10.1016/j.jor.2013.01.001.
  • 9Bessho M, Ohnishi I, Matsuyama J, et al. Prediction of strength and strain of the proximal femur by a CT-based finite element method [J]. J Biomech, 2007, 40(8) : 1745-1753.
  • 10K.oivumaki JE, Thevenot J, Pulkkinen P, et al. Ct-based finite element models can be used to estimate experimentally measured failure loads in the proximal femur[J]. Bone,2012, 50(4) :824-829.