期刊文献+

隔离病房负压监控系统设计与研究

Design and Research of Negative Pressure Monitoring System in Isolation Sard
原文传递
导出
摘要 隔离病房监控系统设计利用负压原理改变风机频率,将空气中的病毒经过特殊处理进行稀释排放,不会污染环境,再经过一系列消毒处理,给医护人员提供更安全的工作环境,挽救更多的生命。本文根据负压病房监控系统的设计,通过PLC的自动控制实现了对风机、风压、温湿度等一系列控制。 The monitoring system of negative pressure isolation ward is designed to use the principle of negative pressure, change the fan frequency, dilute and discharge the virus in the air after special treatment, and will not pollute the environment. After a series of disinfection treatment, it can provide a safer working environment for medical staff and save more lives. According to the design of negative pressure ward monitoring system, this paper realizes a series of control of fan, air pressure, temperature and humidity through the automatic control of PLC.
作者 刘湛梁 张晓萍 张哲 Liu Zhanliang;Zhang Xiaoping;Zhang Zhe(Applied Technology College of Soochow University,Suzhou 215300,China;Tus-Design Group Co.,Ltd,Suzhou 215500,China)
出处 《智能建筑电气技术》 2022年第5期87-90,共4页 Electrical Technology of Intelligent Buildings
关键词 可编程逻辑控制器 负压隔离病房 IFIX 监控系统 PLC negative pressure isolation ward iFIX monitoring system
  • 相关文献

参考文献6

二级参考文献16

共引文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;