摘要
通过潮流计算、稳定校验、电力平衡等分析,论述了安福合环工程对宜昌江南电网运行特效的影响,重点分析了安福合环后宜昌江南地区清洁能源消纳及外送的薄弱点,为电力系统规划、电网运行方式、用户报装接入等方面提供相关参考。
Through the analysis of power flow calculation,stability check and power balance,this paper discusses the influence of Anfu integrated ring project on the special operation effect of Yichang Jiangnan power grid,and then focuses on the analysis of the weak points of clean energy consumption and delivery in the Jiangnan area of Yichang after the operation of Anfu integrated ring,thus providing relevant references for power system planning,power grid operation mode,and user installation and access.
作者
王艳阳
丁红声
周翔
骆卫东
熊会林
童华敏
WANG Yanyang;DING Hongsheng;ZHOU Xiang;LUO Weidong;XIONG Huilin;TONG Huamin(State Grid Suizhou Power Supply Company,Suizhou Hubei 441300,China;State Grid Yichang Power Supply Company,Yichang Hubei 443002,China;College of Electrical Engineering and New Energy,China Three Gorges University,Yichang Hubei 443002,China)
出处
《湖北电力》
2022年第5期37-43,共7页
Hubei Electric Power
基金
国家自然科学基金(项目编号:51907104)
国网宜昌供电公司科学技术项目(项目编号:SGTYHT/19-JS-215)。
关键词
宜昌电网
安福合环
潮流计算
新能源消纳
清洁能源
Yichang power grid
Anfu integrated ring
power flow calculation
new energy consumption
clean energy