摘要
介绍了催化裂化催化剂装置风机及其联轴器的基本情况,针对风机运行中存在的联轴器螺栓频繁断裂事故,进行了原因分析,并提出了解决措施。
The basic situation of the blower fan and its coupling of the catalytic cracking catalyst device was introduced, and the case study was carried out in view of the frequent fracture of the coupling bolt in the operation of the blower fan, and the solution measure was proposed.
出处
《上海电气技术》
2022年第4期70-72,共3页
Journal of Shanghai Electric Technology
基金
中国石化催化剂有限公司科研开发项目(编号:CTAZ200080)。
关键词
风机
联轴器
螺栓
断裂
事故
Blower Fan
Coupling
Bolt
Fracture