摘要 全世界每年大约有1500万婴儿早产,早产是新生儿死亡的主要原因。早期准确预测早产并及时干预对改善妊娠结局及降低早产儿病死率具有重要意义。超声技术通过实时观察宫颈形态及长度变化、评估宫颈硬度值等来预测早产,具有简单便捷、无辐射、可重复性好的优势,在早产预测方面具有非常重要的价值。本文对超声技术评估宫颈预测早产的研究现状进行综述。 Approximately 15 million babies are born prematurely each year worldwide and preterm birth is the leading cause of neonatal death.Early and accurate prediction of preterm birth and timely intervention are of great significance for improving the pregnancy outcomes and reducing the premature infant mortality.Ultrasound technology predicts preterm birth by observing the changes in cervical shape and length in real time,evaluating the cervical hardness,etc.It has the advantages of simplicity,convenience,no radiation,and good repeatability,and has very important values in the prediction of premature birth.This article reviews the current research status of ultrasound technology to assess the cervix uteri for predicting preterm birth.
作者 隋祯慧 唐丽玮 张明珠 董景云 高岩冰 Sui Zhenhui;Tang Liwei;Zhang Mingzhu;Dong Jingyun;Gao Yanbing(Department of Ultrasound Medicine,Binzhou Medical University Hospital,Binzhou 256600,China)
出处 《国际医药卫生导报》 2023年第3期315-318,共4页 International Medicine and Health Guidance News
基金 山东省医药卫生科技发展计划项目(2018WS543)。
关键词 早产 宫颈长度 超声检查 弹性成像 纹理分析 Preterm birth Cervical length Ultrasonography Elastography Texture analysis
  • 相关文献

参考文献7

二级参考文献62

  • 1Bamher J, Cosgrove D, Dietrich CF, et al. EFSUMB guidelines and recommendations on the clinical use of uhrasound elastography. Part 1 : Basic principles and technology[J ]. Ultraschal[ Med, 2013,34 (2) : 169-184.
  • 2Cosgrove D, Piscaglia F, Bamber J, el al. EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 2: Clinical applications [J ]. Uhraschall Med, 2013,3,1(3) :238- 253.
  • 3Sarvazyan A. Hall TJ, Urban MW, et al. An overview of elastography an emerging branch of medical imaging[ J]. Curr Mcd Imaging Rev, 2011,7(4) :255-282.
  • 4Aguilo MA, Aquino W, Brigham JC, et al. An inverse problem approach for elasticity imaging through vibroaeousties [J]. IEEE Trans Med Imaging, 2010,29(4):1012-1021.
  • 5Kibria MG, Hasan MK. A class of kernel based real-time elastography algorithms[J]. Uhrasonics, 2015,61:88-102.
  • 6Stachs A, Dieterich M, Hartmann S, et al. Diagnosis of ruptured breast implants through highresolution ultrasound combined with real time elastography [J]. Aesthet Surg J, 2015,35(1) :410- 418.
  • 7Tudisco C, Bisicchia S, Stefanini M, etal Tendon quality in small unilateral supraspinatus tendon tears. Real-time sonoelastography correlates with clinical findings[J]. Knee Surg Sports Traumatol Arthrosc, 2015,23(2):393- 398.
  • 8Meng F, Zheng Y, Zhang Q, et al. Noninvasive evaluation of liver fibrosis using real time tissue elastography and transient elastography (FihroScan) [J]. J Ultrasound Med, 2015,34 (3):403- 410.
  • 9Pavlov CS, Casazza G, Nikolova D. et al. Transient elastography for diagnosis of stages of hepatic fibrosis and cirrhosis in people with alcoholic liver disease [J]. Cochrane Database Syst Rev, 2015,1 :CD010542.
  • 10Friedrich Rust M, Lupsor M, de Knegt R, et al. Point ShearWave Elastography hy Acoustic Radiation Force Impulse Quantification in Comparison to Transient Elastography for the Noninvasive Assessment of laver Fibrosis in Chronic Hepatitis C, A Prospective International Muhicenter Study [J]. Ultraschall Med, 2015,36(3):239 247.