期刊文献+

钱家营矿局扇不间断电源系统的设计与应用

Design and Application of Uninterruptible Power Supply System for Qianjiaying Mine Bureau Fan
下载PDF
导出
摘要 煤矿井下掘进工作面局扇采用专用变压器、专用线路、专用开关(以下简称“三专”)供电系统,特殊情况下出现市电中断时,大功率不间断电源可以为局扇供电,有效解决局扇双停带来的瓦斯超限等重大隐患。根据局扇耗能进行储能装置容量设计,设计了一种适用于局扇的不间断电源,匹配单体电池容量和个数,使电池组处于最佳工作状态。基于系统的控制器对传统“三专”供电网络进行监测,加装防止反送电装置和智能切换器,实现局扇供电电源从市电向蓄电池、逆变式充电机、变频调速逆变器以及升压器作为电能转换装置的智能切换,并实现局扇运行状态监控和相关报警功能。同时接入矿井智能化监控管理平台,实现远程监控和报警,提高矿井工作面的安全性和可靠性,保证工作面人员的生命安全。 The power supply system for the local fan in the coal mine underground tunneling face is special transformer,special line and special switch(hereinafter referred to as“three special”).When the commercial power is interrupted under special circumstances,the high-power uninterruptible power supply can supply power for the local fan,effectively solving the major hidden dangers such as gas overrun caused by double stop of the local fan.According to the energy consumption of local fan,the capacity of energy storage device is designed,and an uninterruptible power supply suitable for local fan is designed,which matches the capacity and number of single batteries to make the battery pack in the best working state.The controller based on the system monitors the traditional“three-specialized”power supply network,and at the same time,an anti-reverse power transmission device and an intelligent switch are installed to realize the intelligent switching of the local fan power supply from the commercial power to the battery,the inverter charger,the variable frequency speed inverter and the booster as the power conversion devices,and realize the monitoring of the local fan operation state and the related alarm functions.At the same time,it is connected to the mine intelligent monitoring and management platform to realize remote monitoring and alarm,improve the safety and reliability of the mine working face and ensure the life safety of the working face personnel.
作者 张海坡 ZHANG Haipo(Kailuan Qianjiaying Mining Company,Tangshan 063300,China)
出处 《通信电源技术》 2023年第3期114-117,共4页 Telecom Power Technology
关键词 局扇不间断电源 储能和逆变智能切换 智能控制技术 远程监视报警 local fan uninterruptible power supply energy storage and inverter intelligent switching intelligent control technology remote monitoring and alarm
  • 相关文献

参考文献8

二级参考文献9

  • 1卢其威,程红,王聪.增设局部通风机应急电源的思考及可行性分析[J].煤炭科学技术,2008,36(3):71-73. 被引量:8
  • 2[1]李成章,王叔芳.新型UPS不间断电源原理与维修技术[M].北京:电子工业出版社,1996.10.
  • 3[1]黄俊,王兆安.电力电子技术(第3版)[M].北京:机械工业出版社,1999.12.
  • 4国家煤矿安全监察局.2004-2009煤矿事故调查报告[R],2010.
  • 5国家煤矿安全监察局.关于加强煤矿供用电安全工作的意见[R].2007.
  • 6国家煤矿安全监察局.矿用隔爆(兼本安)型锂离子蓄电池电源安全技术要求[R],2011.
  • 7王其英.UPS不间断电源剖析与应用.北京:科学出版社,1997
  • 8MalesaniL,MattavelliP,TomasinP.High-performancehysteresismodulationtechniqueforactivefilter[]..1996
  • 9Chen J F,Chu C L.Combination voltage-controlled and current- controlled PWM inverter for UPS parallel operation[].IEEE Transactions on Power Electronics.1995