摘要 归纳总结了疫苗洁净厂房建筑给水排水相关的先行设计规范。针对疫苗洁净厂房建筑给水排水系统设计与常规建筑不同的特点,强调了水质安全、可靠的原则。分析了病毒类疫苗生产厂房在给水和排水系统的设计要点,总结了设计水量计算的参数及要求,以及工艺水水质处理工艺流程和分配系统的特殊要求。 The advance design code for water supply and drainage of new coronavirus vaccine manufacturing plant was summarized.According to the different characteristics of water supply,drainage and fire control system design in medical buildings,the principles of safe and reliable water quality are emphasized.The main points of design of water supply,drainage and fire control system in the workshop of new coronavirus pneumonia vaccine production were analyzed,and the design requirements were summarized.
作者 刘海 夏树威 杨巧云 尧桂龙 LIU Hai;XIA Shuwei;YANG Qiaoyun;YAO Guilong(China Architecture design&Research group,Beijing 100044,China;Shanghai Pudong Architecural Design and Research Insitute Co.,Ltd.,Shanghai 201206,China)
出处 《给水排水》 CSCD 北大核心 2023年第6期75-79,共5页 Water & Wastewater Engineering
关键词 疫苗厂房 给水排水 纯化水 注射用水 生产废水 Vaccine factory Water supply and drainage system Purified water Water for injection Production effluent
  • 相关文献

参考文献4

二级参考文献15

  • 1国家药品监督管理局.YY0033-2000.无菌医疗器具生产管理规范[S].
  • 2谭天恩,窦梅,周明华,等.化工原理[M].北裒化学工业出版社,2006:16.
  • 3国家食品药品监督管理局药品安全监管司等.药品生产验证指南[M].北京:化学工业出版社,2003,95-96.
  • 4ISPE. Pharmaceutical engineering guides for new and renovated facilities.volume4 water and steam system[M], USA. 2001: 102, 252.
  • 5中国医药工程设计协会.医药工业洁净厂房设计规范[M].北京:中国计划出版社,2009,15.
  • 6中国建筑设计研究院.CECS153-2003.建筑给水薄壁不锈钢管管道工程技术规程[s].北京:中国计划出版社.2003,8.
  • 7中华人民共和国药典(二部),2005
  • 8贾正成,周霞.甲类医药洁净厂房消防设计研究[J].武警学院学报,2011,27(10):32-34. 被引量:2
  • 9靳军宝,秦英杰,王奔,王彬,崔东胜,刘立强.高温多效膜蒸馏用于处理高盐溶液的实验研究[J].化学工业与工程,2014,31(2):31-37. 被引量:5
  • 10罗吉安,刘德华,粟好进,赵雪冰.1,3-丙二醇发酵液蒸发脱水的工艺模拟[J].化工进展,2017,36(3):810-815. 被引量:3

共引文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部