摘要
归纳总结了疫苗洁净厂房建筑给水排水相关的先行设计规范。针对疫苗洁净厂房建筑给水排水系统设计与常规建筑不同的特点,强调了水质安全、可靠的原则。分析了病毒类疫苗生产厂房在给水和排水系统的设计要点,总结了设计水量计算的参数及要求,以及工艺水水质处理工艺流程和分配系统的特殊要求。
The advance design code for water supply and drainage of new coronavirus vaccine manufacturing plant was summarized.According to the different characteristics of water supply,drainage and fire control system design in medical buildings,the principles of safe and reliable water quality are emphasized.The main points of design of water supply,drainage and fire control system in the workshop of new coronavirus pneumonia vaccine production were analyzed,and the design requirements were summarized.
作者
刘海
夏树威
杨巧云
尧桂龙
LIU Hai;XIA Shuwei;YANG Qiaoyun;YAO Guilong(China Architecture design&Research group,Beijing 100044,China;Shanghai Pudong Architecural Design and Research Insitute Co.,Ltd.,Shanghai 201206,China)
出处
《给水排水》
CSCD
北大核心
2023年第6期75-79,共5页
Water & Wastewater Engineering
关键词
疫苗厂房
给水排水
纯化水
注射用水
生产废水
Vaccine factory
Water supply and drainage system
Purified water
Water for injection
Production effluent