期刊文献+

梅江干流合江水电站增效扩容改造安全复核研究 被引量:2

Safety Review of Efficiency Increase,Capacity Expansion Reconstruction of Hejiang Hydropower Station in the Mainstream of Meijiang River
下载PDF
导出
摘要 为进一步提高梅江干流合江水电站运行效率,计划实施增效扩容改造。基于静力平衡理论对电站的厂房稳定、左岸挡墙、水闸过流能力、水闸稳定进行计算分析,各项指标达到电站改造安全稳定要求,可为类似电站改造工程提供参考。 To further enhance the operational efficiency of Hejiang Hydropower Station in the Meijiang Mainstream,there are plans to implement efficiency enhancement and capacity expansion reconstruction.Based on the theory of static equilibrium,calculations and analyses will be conducted on the stability of the power plant building,the left bank retaining wall,the spillway capacity,and the stability of the spillway.All indicators will meet the safety and stability requirements for the station's reconstruction which can provide a reference for similar hydropower station reconstruction projects.
作者 黄学宇 HUANG Xue-yu(Meizhou Water Resources and Hydropower Survey and Design Institute Co.,Ltd.,Meizhou 514000,China)
出处 《海河水利》 2023年第8期117-119,共3页 Haihe Water Resources
关键词 梅江干流 水电站 扩容改造 安全复核 稳定 Meijiang mainstream hydropower station expansion reconstruction safety review stable