基于理想气体状态方程的气动执行机构气密性检测方法 被引量:2

Air-tightness Detection Method of Pneumatic Actuator Based on Ideal Gas State Equation
下载PDF
导出
摘要 为在缺少专业测量仪器的情况下,定量检测出气动执行机构密封试验的泄漏率,提出一种基于理想气体状态方程的气密性定量检测方法。该方法利用理想气体状态方程和已知的允许最大泄漏率,推导出气动执行机构在气密性试验一定保压时间内的最大允许压降。通过测量气密性试验保压前后的压降,可判断气动执行机构气密性试验是否满足最大泄漏率的要求。 In order to quantitatively detect the leakage rate of the pneumatic actuator in the leakage test when lacking of professional measuring instrument.A quantitative test method of leakage test based on equation of state for ideal gas is proposed.This method uses the ideal gas state equation and the known maximum allowable leakage rate to derive the maximum allowable pressure drop of the pneumatic actuator in a certain holding time of the leakage test.By measuring the pressure drop before and after the leakage test,it can be judged whether the tightness of the pneumatic actuator meets the requirements of the maximum leakage rate.
作者 姜国微 王利敏 陈蒙南 JIANG Guo-wei;WANG Li-min;CHEN Meng-nan(Wuxi Force&Torque Technology Co.,Ltd.,Wuxi 214191,Jiangsu,China)
出处 《阀门》 2023年第5期564-566,共3页 VALVE MAGAZINE
关键词 理想气体状态方程 气密性试验 气动执行机构 压降 equation of state for ideal gas leakage test pneumatic actuator pressure drop
  • 相关文献

参考文献7

二级参考文献16

  • 1吴宏星.理想气体状态方程在日常生活中的应用[J].福建广播电视大学学报,2006(2):76-78. 被引量:1
  • 2余守宪.真实气体与气液相变[M].北京:人民教育出版社,1981..
  • 3赵克林 宋孝光 李铁盘.范德瓦耳斯方程纵横谈[J].物理通报,1995,(11):15-17.
  • 4ASTM D 792-2000 Standard test methods for density and specific gravity (relative density) of plastics by displacement
  • 5ASTM D 1505-1985 Density of plastics by the density gradient technique
  • 6GB/T111115低密度聚乙烯树脂
  • 7GB/T111116高密度聚乙烯树脂
  • 8ISO 1183-87 Plastics methods for determining the density and relative density of non -celluiar plastics
  • 9GB/T 1033-86塑料密度和相对密度试验方法
  • 10顾江鸿,郑少山,侯丹.利用等温变化规律测量大气压强的简单方法[J].中学物理,2010(7):27-27. 被引量:2