期刊文献+

某宽厚钢板等离子切割开裂原因 被引量:1

Causes of plasma cutting cracking of a wide and thick steel plate
下载PDF
导出
摘要 在某宽厚板的等离子切割工序中,其板厚1/2处产生中心裂纹。采用宏观观察、化学成分分析、金相检验、扫描电镜及能谱分析、硬度测试等方法分析该钢板开裂的原因。结果表明:在钢板1/2厚度处存在明显的偏析带,基体和偏析带的显微组织分别为回火马氏体和淬火马氏体,在偏析带中分布有长条状夹杂物,裂纹从夹杂物处萌生并扩展;等离子切割后的淬硬层硬度较大,具有很大的淬硬倾向,在热应力和组织应力的作用下,钢板最终开裂。 In the plasma cutting process of a wide and thick plate,a central crack was generated at 1/2 thickness of the plate.The causes of cracking of the steel plate were analyzed by means of macroscopic observation,chemical composition analysis,metallographic examination,scanning electron microscope and energy spectrum analysis and hardness test.The results show that there was an obvious segregation band at 1/2 thickness of the steel plate.The microstructures of the matrix and the segregation band were tempered martensite and quenched martensite,respectively.There were long strip inclusions in the segregation band,and the cracks initiated and propagated from the inclusions.The hardened layer after plasma cutting had a large hardness and a great tendency to harden.Under the action of thermal stress and structural stress,the steel plate eventually cracked.
作者 何婷 何志辉 邓家林 HE Ting;HE Zhihui;DENG Jialin(Hunan Sany Industrial Vocational and Technical College,Changsha 410100,China;Sany Heavy Industry Co.,Ltd.,Changsha 410100,China)
出处 《理化检验(物理分册)》 CAS 2023年第9期57-61,共5页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 宽厚板 等离子切割 淬硬层 偏析带 wide and thick plate plasma cutting hardened layer segregation band
  • 相关文献

参考文献9

二级参考文献43

共引文献10

同被引文献9

引证文献1

  • 1宋全,李晗,淡婷,张国庆,徐宋娟,颜明礼.45钢环断裂原因[J].理化检验(物理分册),2024,60(6):34-36.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部