摘要
阐述跌落式熔断器的工作原理,分析10kV跌落式熔断器故障的原因,包括易烧坏熔管、熔丝易断,提出防止跌落式熔断器故障的应对措施,从而保障电网的正常运行。
This paper describes the working principle of drop-type fuses,analyzes the causes of 10kV drop-type fuse faults,including easily burnt fuse tubes and easily broken fuses,and proposes countermeasures to prevent drop-type fuse faults,in order to ensure the normal operation of the power grid.
作者
倪伟
宫衍平
王欣悦
马丽雅
NI Wei;GONG Yanping;WANG Xinyue;MA Liya(Nanjing Yuanneng Intelligent Power Supply Branch,Jiangsu 210046,China)
出处
《电子技术(上海)》
2023年第9期244-245,共2页
Electronic Technology