期刊文献+

超超临界锅炉水冷壁鳍片裂纹原因分析及整治 被引量:1

Cause Analysis and Treatment of Fin Crack on Water Wall of Ultra Supercritical Boiler
下载PDF
导出
摘要 水冷壁是电站锅炉主要的受热面之一。某电厂超超临界锅炉在投入运行3年后,发现前墙水冷壁向炉内凹陷,并且鳍片出现纵向裂纹,最终导致水冷壁管泄漏。通过分析主要原因为锅炉设计理论与实际运行有差异,加上锅炉安装缺陷所导致,针对原因提出了整治措施,并提出了预防措施,从而保障锅炉安全运行,为其他电厂提供了参考。 The water wall is one of the main heating surfaces of the power plant boiler.After the ultra supercritical boiler in a power plant was put into operation for 3 years,it was found that the front wall water wall was sunken into the boiler,and the fins had longitudinal cracks,which eventually led to the leakage of the water wall tubes.Through analysis,the main reasons are the difference between the boiler design theory and the actual operation,and the boiler installation defects.In addition,the rectification measures and preventive measures are proposed for the reasons,so as to ensure the safe operation of the boiler,which can provide reference for other power plants.
作者 王金潆 Wang Jinying(SDIC Yunding Meizhouwan Power Co.,Ltd,Putian 351100)
出处 《中国特种设备安全》 2023年第11期80-84,共5页 China Special Equipment Safety
关键词 超超临界锅炉 水冷壁 鳍片裂纹 Ultra supercritical boiler Water wall Fin crack
  • 相关文献

参考文献3

二级参考文献16

共引文献4

同被引文献8

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部