期刊文献+

通道间串扰测量不确定度评定

Uncertainty Evaluation of Crosstalk Measurement Between Channels
下载PDF
导出
摘要 针对通道间串扰校准评价离散性较大并且受测量系统本底噪声和偏移影响严重的问题,提出了使用绝对值的平均值计算干扰分量值以降低离散性,通过绝对值幅度合成法剔除本底噪声和偏移的影响,从而获得离散性良好、受本底噪声与直流偏移影响较低的通道间串扰测量结果。并基于该方法与流程,讨论了不确定度的来源,主要包括信号源误差、数据采集系统增益误差、幅度分辨力误差、测量通道直流偏移、干扰本身的测量误差、本底噪声的测量误差和测量重复性等,并建立了不确定度模型。最后结合实例,给出了通道间串扰的不确定度评价结果,验证了所述方法的实用性与可行性。 In order to solve the problem of high discreteness in the evaluation of inter channel crosstalk calibra-tion and the serious impact of measurement system background noise and offset,it is proposed to use the aver-age of absolute values to calculate the interference component value to reduce discreteness.By synthesizing the amplitude of absolute values to eliminate the impact of background noise and offset,the inter channel crosstalk measurement results with good discreteness and low impact from background noise and DC offset are obtained.Based on this method and process,the sources of uncertainty are discussed,including signal source error,data acquisition system gain error,amplitude resolution error,measurement channel DC offset,measurement error of interference itself,measurement error of background noise,and measurement repeatability.An uncertainty mod-el is established.Finally,combined with an example,the uncertainty evaluation results of inter channel crosstalk are provided,which can verify the practicality and feasibility of the proposed method.
作者 梁志国 冯秀娟 LIANG Zhiguo;FENG Xiujuan(National Key Laboratory of Metrology and Calibration Technology,AVIC Bejjing Changcheng Institute of Metrology and Measurement,Beijing 100095,China;Di vision of Mechanics and Acoustics Metrology,National Institute of Metrology,China,Bejng 100029,China)
出处 《测控技术》 2023年第11期53-57,共5页 Measurement & Control Technology
基金 国家市场监管总局规范修订项目(2021-237)。
关键词 计量学 不确定度 通道间串扰 评价 校准 数据采集系统 metrology uncertainty crosstalk between channels evaluation calibration data acquisition system
  • 相关文献

参考文献8

二级参考文献30

  • 1程晓畅,王跃科,潘仲明.基于最小二乘估计的数据采集通道标定方法[J].计算机测量与控制,2005,13(9):997-999. 被引量:3
  • 2王新元,程瑞端,沈炳耘,李时东.多路温度采集仪器的标定与数据分析[J].仪器仪表与分析监测,2006(4):26-28. 被引量:3
  • 3.JJF 1057-1998.数字存储示波器[S].,1998..
  • 4GJB3756-1999.测量不确定度的表示及评定[S].[S].叶德培,宋振国,汪贤至北京:中国人民解放军总装备部军标出版发行部,1999..
  • 5Deyst J P, Soulders T M, Solomon O M Jr. Bounds on Least-Squares Four-Parameter Sine-Fit Errors Due to Harmonic Distortion and Noise[J]. IEEE Trans on I M, 1995, 44(3): 637-642.
  • 6Soulders T M. The Effects of Timing Jitter in Sampling Systems[J]. IEEE Trans on I M, 1990, 39(1): 80-85.
  • 75700A/5720A Series II Multifunction Calibrator Service Manual[M]. Fluke Corporation, 1996, 1-39.
  • 8Liang Zhiguo, Zhu Jijie. A Digital Filter for the Single Frequency Sinusoid Series[J]. Transactions of Nanjing University of Aeronautics & Astronautics, 1999, 16(2): 14-16.
  • 9JJF1057-1998.数字存储示波器[S].[S].,..
  • 10Liang Zhiguo, Lu Kejie, Sun Jingyu. Evaluation of Software of Four-parameter Sine Wave Curve-fit[J]. Transactions of Nanjing Uniνersity of Aeronautics & Astronautics, 2000, 17(1): 100-106.