针对当前装配式叠合板后浇板带与拼缝细部节点施工问题,提出后浇板带与拼缝细部节点施工技术,解决了装配式叠合板后浇带与拼缝细部节点施工环节存在的漏浆及翘起问题,实现装配式叠合板后浇板带施工质量的全面提升。
Aiming at the construction problems of post-cast strip and flat-fell seam detail node of assembled composite slab,people put forward the construction technology of post-cast strip and flat-fell seam detail node,which solved the problems of slurry leakage and warping in the construction of post-cast strip and flat-fell seam detail node of assembled composite slab,and realized the overall improvement of construction quality of post-cast strip.
作者
邵建鹏
刘志超
曹胜源
蔡胜辉
SHAO Jian-peng;LIU Zhi-chao;CAO Sheng-yuan;CAI Sheng-hui(China Construction Second Engineering Bureau 2nd Construction Engineering Co.Ltd.,Shenzhen 518000,China)
出处
《工程建设与设计》
2023年第23期195-197,共3页
Construction & Design for Engineering
关键词
装配式
叠合板
后浇板带
拼缝细部节点
Jassembly type
composite slab
post-casting strip
flat-fell seam detail node