摘要
对天津某地铁车站的空调制冷系统进行节能技术分析,通过优化空调系统设计和高效设备选型,结合风水联动智能系统控制风-水系统高效运行,实现制冷机房的高能效、低能耗,相比常规地铁车站制冷系统的能效有大幅提升,制冷机房的EERS能达到5.3以上,制冷系统的耗电量显著减少,约节省能耗40%。
An energy-saving technology analysis was conducted on the air conditioning and refrigeration system of a subway station in Tianjin.By optimizing the design of the air conditioning systemand selecting efficient equipment,combinedwith the intelligent systemofwind water linkage to control the efficient operation of the air water system,high energy efficiency and low energy consumption of the refrigeration room were achieved.Compared with the energy efficiency of the refrigeration system of conventional subway stations,the EERS of the refrigeration machine room can reach more than 5.3,and the power consumption of the refrigeration system is significantly reduced,saving about 40% of energy consumption.
作者
潘帅方
PAN Shuai-fang(China Railway Shanghai Design Institute Group Co.Ltd.,Tianjin 300000,China)
出处
《工程建设与设计》
2024年第1期80-83,共4页
Construction & Design for Engineering
关键词
高效制冷机房
风水联动智能控制系统
节能
efficient refrigeration room
intelligent control systemfor air conditioning systems andwater systems
energy conservation