期刊文献+

温度波动对螺栓法兰连接系统垫片应力的影响

Influence of temperature and pressure fluctuations on gasket stress in bolted flange connection systems
下载PDF
导出
摘要 温度波动会造成螺栓法兰连接系统中垫片应力松弛,从而影响其密封性能。文章以DN80法兰接头为研究对象,通过ABAQUS软件建立了三维有限元模型,分析了温度波动对垫片应力的变化,研究了垫片与螺栓载荷变化的机理。结果表明,螺栓法兰连接系统在温度变化时存在着一定的温度滞后现象;当温度波动时,垫片应力随温度的降低而减小,随温度的升高而增大,波动结束后垫片表现出“内紧外松”的应力分布现象。在这一过程中,垫片的热膨胀与温度场的滞后性是垫片应力变化的主要因素。研究结果为螺栓法兰连接系统的进一步优化和改进提供了有力支持。 The relaxation of gasket stresses in bolted flange connection systems,induced by temperature fluctuations,can subsequently affect their sealing performance.This paper focuses on DN80 flange joints,utilizing ABAQUS software to analyze the variation of gasket stresses induced by temperature fluctuations.The study investigates the mechanisms governing gasket and bolt load changes.The findings reveal that the bolted flange connection system exhibits a certain temperature lag phenomenon during temperature variations.When temperature fluctuates,gasket stresses decrease with declining temperature and increase with rising temperature.Following the temperature fluctuations,the gasket exhibits a stress distribution pattern known as“inner tightening and outer loosening”.During this process,gasket thermal expansion and the hysteresis of the temperature field play a pivotal role in gasket stress variations.The research results provide valuable insights and support for the further optimization and improvement of bolted flange connection systems.
作者 孔靖 邵春雷 Kong Jing;Shao Chunei(School of Mechanical and Power Engineering,Nanjing Tech University,Nanjing 211816,China;College of Emergency Management,Nanjing Tech University,Nanjing 211816,China)
出处 《新能源科技》 2024年第1期24-30,共7页 New energy technology
基金 国家重点研发计划项目(2020YFB2008000)。
关键词 螺栓法兰连接系统 温度波动 瞬态温度 垫片应力 bolted flange connection system temperature fluctuation transient temperature gasket stress
  • 相关文献

参考文献4

二级参考文献25

  • 1陆晓峰,顾伯勤,涂善东.高温螺栓法兰连接研究进展[J].压力容器,2004,21(12):34-41. 被引量:15
  • 2王俊和,蔡仁良,钟伟明.在稳态温度场中法兰接头的三维有限元分析[J].压力容器,2005,22(10):18-22. 被引量:11
  • 3顾伯勤,陈晔.高温螺栓法兰连接的紧密性评价方法[J].润滑与密封,2006,31(6):39-41. 被引量:49
  • 4顾伯勤 蒉纪山.法兰连接中螺栓和垫片载荷的确定[J].南京化工大学学报,1988,10(4):1-6.
  • 5周先军,仇性启,张兵,陈国明.螺栓联接法兰瞬态温度场分析[J].压力容器,2007,24(7):8-11. 被引量:8
  • 6Nechache A, Bouzid A. The Determination of Load Changes in Bolted Gasketed Joints Subjected to Elevated Temperature[ A]. Proceedings of PVP2003 [ C ]. 2003 ASME Pressure Vessels and Piping Division conference ,2003 : 139 - 148.
  • 7Muhammad Abid. Determination of Safe Operating Conditions for Gasketed Flange Joint under Combined Internal Pressure and Temperature:A Finite Element Approach [ J ]. International Journal of Pressure Vessels and Piping,2006,83(6) : 433 -441.
  • 8ASME.Rules for Construction of Pressure Vessels,Section VIII,Division 1[S].New York:ASME,1989.
  • 9Deutsches Institute für Normung.DIN 2505 Berechnung von Flanschverbindungen[S].Berlin:Beuth Verlag GmbH,1990.
  • 10Gu Boqin.Reproduzierbarkeit and Vergleichbarkeit von Lssig-keitsmebverfahren[D].Leoben:Montanuniversitt Leoben,1996.