摘要 化工园区废水成分复杂,难降解物质多。某化工园区污水处理厂选用分质强化混凝沉淀+臭氧氧化作为预处理工艺,同时采用水解酸化+厌氧好氧(Anaerobic/Oxic,A/O)的二级处理工艺和混凝沉淀+臭氧氧化的深度处理工艺。实际运行结果表明,该组合工艺对化学需氧量(Chemical Oxygen Demand,COD)的平均去除率为85.7%,COD去除效果良好,出水水质优于《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级A标准。 The composition of wastewater in chemical industrial parks is complex,and there are many difficult to degrade substances.A sewage treatment plant in a certain chemical industrial park adopts a pre-treatment process of qualitative enhanced coagulation sedimentation+ozone oxidation,while adopting a secondary treatment process of hydrolysis acidification+Anaerobic/Oxic(A/O)and a deep treatment process of coagulation sedimentation+ozone oxidation.The actual operation results show that the average removal rate of Chemical Oxygen Demand(COD)by this combination process is 85.7%,and the COD removal effect is good,and the effluent quality is superior to the first level a standard of the"Pollutant Discharge Standard for Urban Sewage Treatment Plants"(GB 18918—2002).
作者 赵海洲 羌金凤 徐芸蔚 ZHAO Haizhou;QIANG Jinfeng;XU Yunwei(East China Branch of China Machinery International Engineering Design&Research Institute Co.,Ltd.,Nanjing 210023,)
出处 《中国资源综合利用》 2024年第3期195-199,共5页 China Resources Comprehensive Utilization
关键词 化工废水 分质处理 混凝沉淀 臭氧氧化 厌氧好氧(A/O) chemical wastewater qualitative treatment coagulation sedimentation ozone oxidation Anaerobic/Oxic(A/O)