期刊文献+

水电站蓄电池组多模块协同阻断技术研究

Research on Multi-module Collaborative Blocking Technology ofHydropower Station Battery Pack
下载PDF
导出
摘要 蓄电池作为水电站中常用的储能设备,能够为电力系统提供稳定的备用电源,并满足水电站在电网停电或负荷波动时的供电需求。铅酸蓄电池以其容量大、寿命长、成本相对较低、充放电效率高和维护成本低等优点而在水电站得到广泛应用。然而,由于频繁的充放电,铅酸蓄电池易发生老化,所以当蓄电池出现开路故障时,会对整个水电站的电源安全构成严重威胁。因此文章基于目前较成熟的开路续流装置设计了一种新型铅酸蓄电池组装置,用于解决水电站铅酸蓄电池组开路故障问题。 As commonly used energy storage devices in hydroelectric power stations,Storage battery can provide stable backup power to the power system and meet the power supply requirements of hydroelectric power stations during grid outages or load fluctuations.Lead-acid batteries are widely applied in hydroelectric power stations due to their advantages of high capacity,long lifespan,relatively low cost,high charge-discharge efficiency,and low maintenance costs.However,due to frequent charge and discharge cycles,lead-acid batteries are prone to aging.When an open circuit fault occurs in the battery,it poses a severe threat to the overall power security of the hydroelectric power station.Therefore,based on the design of a novel open-circuit continuous current device that is relatively mature at present,this paper proposes a new assembly for lead-acid battery groups,aimed at addressing the open circuit fault issue in hydroelectric power station battery groups.
作者 方建文 邬建春 秦谱 赵坤 施林全 FANG Jianwen;WU Jianchun;QIN Pu;ZHAO Kun;SHI Linquan
出处 《电力系统装备》 2024年第2期22-23,104,共3页 Electric Power System Equipment
关键词 铅酸蓄电池 蓄电池组故障 多电池串联 跨接模式 开路续流装置 lead-acid battery battery group fault multi-battery series connection bypass mode open-circuit continuous current device
  • 相关文献

参考文献6

二级参考文献33

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部