水平多层spiral型地埋管数值模拟研究及换热特性分析

Numerical simulation and the Heat Transfer Performance of Multi-layers Horizontal Spiral Coil Ground Heat Ex-changer
下载PDF
导出
摘要 本文基于COMSOL软件建立了水平spiral型多层地埋管群传热三维数值模拟模型,并对其换热性能和温度场进行分析研究。结果表明:对比水平spiral多层并联管群来说,远离注入端的地埋管管内温度相对较低。地埋管群周围地层温度有所升高,远离注入端的地层温度变化相对较小。地埋管群的换热量随循环流体的流速增加而增加,但增幅降低。在进行换热器设计时,应合理控制循环水的流速。3层螺旋地埋管群的换热量略高,但层间干扰明显,建议选用2层并联螺旋管群。 A three-dimensional numerical simulation model of multi-layers horizontal spiral coil ground heat ex-changer group(HSCGHEG)was established Based on COMSOL software.The heat transfer performance and temperature field of multi-layers HSCGHEG were studied.The results show that the fluid temperature in multi-layers HSCGHEG far from the injection point is relatively low.The formation temperature around the multi-layers HSCGHEG increases,and the formation temperature away from the injection point changes relatively small.The heat transfer capacity of multi-layers HSCGHEG increases with increasing of circulating fluid flow rate,but the increase rate decreases.The flow rate of circulating fluid should be designed reasonably.The heat transfer capacity of the 3-layers HSCGHEG is slightly higher than that of the 2-layers HSCGHEG,but the interference between layers is obvious.So it is recommended to choose the 2-layers HSCGHEG.
作者 高英 谷峰 张越 崔景云 蒋时馨 Gao Ying;Gufeng;Zhang Yue;Cui Jingyun;Jiang Shixin(Technology R&D Center,CNOOC Gas and Power Group,Beijing 100028)
出处 《石化技术》 CAS 2024年第4期48-50,共3页 Petrochemical Industry Technology
关键词 水平螺旋地埋管换热器 传热特性 数值模拟 多层 地埋管群 Horizontal spiral coil ground heat ex-changer Heat transfer characteristics Numerical simulation Multi-layers ground heat ex-changer Ground heat ex-changer group
  • 相关文献

参考文献1

二级参考文献10

  • 1孙红玉,章程程,巩学梅.地源热泵桩埋管换热器设计计算及经济性分析[J].四川建材,2012,38(2):278-280. 被引量:2
  • 2宋小飞,温治,司俊龙.地源热泵U型管地下换热器的CFD数值模拟[J].北京科技大学学报,2007,29(3):329-333. 被引量:27
  • 3Man Yi, Yang Hongxing, Diao Nairen, et al. A new model and analytical solutions for borehole and pile ground heat exehangers[J]. International Journal of Heat and Mass Transfer,2010,53 .2593-2601.
  • 4Yang H, Cui P, Fang Z. Vertical-borehole ground-cou- pled heat pumps:a review of models and systems[J]. Applied Energy,2010,87(1) : 16-27.
  • 5Wu Y,Gan G,Verhoef A, et al. Experimental meas- urement and numerical simulation of horizontal-cou- pled slinky ground source heat exchangers[J]. Applied Thermal Energy, 2010,30 : 74-83.
  • 6Congedo P M, Colangelo G, Starace G. CFD simula- tions of horizontal ground heat exchangers:a compari- son among different configurations[J]. Applied Ther- mal Energy,2012,33 .24-32.
  • 7Piechowski M. Heat and mass transfer model of a ground heat exchanger: theoretical development [J]. International Journal of Energy Research, 1999,23: 571-588.
  • 8Pieehowski M. Heat and mass transfer model of a ground heat exchanger: validation and sensitivity a- nalysis [J]. International Journal of Energy Research, 1998,22 : 965-979.
  • 9郑红旗,张建忠,陈九法.地埋管换热器形式、管径及岩土温度对其换热性能的影响[J].暖通空调,2012,42(5):90-95. 被引量:12
  • 10桂树强,程晓辉,张志鹏.地源热泵桩基与钻孔埋管换热器换热性能比较[J].土木建筑与环境工程,2013,35(3):151-156. 被引量:30

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部