摘要 目的:探究一种心电监护仪的导联线固定器临床应用效果。方法:纳入2022年8月~2023年7月于赣州市妇幼保健院就诊的接受心电监护治疗时长超过5d的患者共84例作为研究对象,采用随机数字表法将所有观察对象分为对照组(n=42)和观察组(n=42)。对照组采用一般的心电监护仪导联线整理方案,观察组采用心电监护仪的导联线固定器。比较两组患者心电监护过程中不良反应事件发生率、护理满意度以及护理人员整理导联线用时。结果:不良事件方面,两组患者的总报修次数共计8次,导联线总脱落次数共计161次。其中,对照组患者脱落率为76.40%(123次),报修率为87.50%(7次);观察组患者脱落率为23.60%(38次),报修率为12.50%(1次);观察组患者的导联线报修率、脱落率以及导联线整理时间均显著低于或少于对照组(P<0.05)。观察组护理满意度调查表总评分相较于对照组明显更高(P<0.05)。结论:相较于传统心电导联整理法,采用心电监护仪的导联线固定器操作更简便、效率更高,能有效减少导联线折损、提高患者满意度。 Objective:To explore the application effect of a lead wire fixator for ECG monitor.Methods:A total of 84 patients who received electrocardiogram monitoring treatment for more than 5 days at Ganzhou Maternal and Child Health Care Hospital from August 2022 to July 2023 were included as the study subjects.All observation subjects were randomly divided into a control group(n=42)and an observation group(n=42)using a random number table method.The control group used the traditional ECG monitor lead wire arrangement method,and the observation group used the ECG monitor lead wire fixation device.The incidence of adverse events,nursing satisfaction and the time spent by nursing staff arranging the lead lines were compared between the two groups.Results:In terms of adverse events,the total number of repairs reported by the two groups of patients was 8 times,and the total number of lead wire dropouts was 161 times.Among them,the dropout rate of the control group patients was 76.40%(123 times),and the repair rate was 87.50%(7 times);The dropout rate of patients in the observation group was 23.60%(38 times),and the repair rate was 12.50%(1 time);The lead repair rate,dropout rate,and lead sorting time of the observation group patients were significantly lower than or less than those of the control group(P<0.05).The total score of the nursing satisfaction questionnaire in the observation group was significantly higher than that in the control group(P<0.05).Conclusion:Compared with the traditional cardiac conductance arrangement method,the lead wire fixation device using ECG monitor is more simple and efficient,and can effectively reduce the lead line loss and improve patient satisfaction.
作者 邱冬梅 彭小燕 QIU Dong-mei;PENG Xiao-yan(Ganzhou Maternal and Child Health Care Hospital,Jiangxi Ganzhou 341000)
出处 《中国医疗器械信息》 2024年第7期135-137,共3页 China Medical Device Information
基金 赣州市科技计划项目(项目名称:一种心电监护仪的导联线固定器应用效果研究,项目编号:GZ20222ZSF342)。
关键词 心电监护仪 导联线固定器 常规心电导联整理法 护理满意度 ECG monitor lead wire holder conventional cardiac conductance finishing method nursing satisfaction
  • 相关文献

参考文献12

二级参考文献125

共引文献172

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部