期刊文献+

高频局放带电指示器设计

Design of High Frequency Partial Discharge Charged Indicator
下载PDF
导出
摘要 文章首先分析高频局部放电(以下简称局放)的原理,其次探讨高频局放信号的特征和传播与衰减规律,最后阐述高频局放带电指示器的设计,包括总体架构设计、信号处理电路设计和信号处理算法与软件系统开发。所设计的高频局放带电指示器能够实现对设备带电状态的精准监测,可以快速响应设备带电状态的变化,为电力系统的安全监测和故障预警提供了有效手段。 This paper first analyzes the principle of high frequency partial discharge(hereinafter referred to as partial discharge),then discusses the characteristics of high frequency partial discharge signal and the law of propagation and attenuation,and finally expounds the design of high frequency partial discharge live indicator,including the overall architecture design,signal processing circuit design,signal processing algorithm and software system development.The designed high frequency local discharge indicator can realize the accurate monitoring of the equipment's charging state,and can quickly respond to the change of the equipment's charging state,which provides an effective means for the safety monitoring and fault warning of the power system.
作者 王骅 张正昕 潘莹 王哲斐 贺润平 WANG Hua;ZHANG Zhengxin;PAN Ying;WANG Zhefei;HE Runping(State Grid Shanghai Electric Power Company South Power Supply Company,Shanghai 201199;Shanghai Muyun Technology Co.,Ltd.,Shanghai 201613)
出处 《现代制造技术与装备》 2024年第6期182-184,共3页 Modern Manufacturing Technology and Equipment
关键词 高频局放 带电指示器 带电状态 监测 high frequency partial discharge live indicator charged state monitor
  • 相关文献

参考文献5

二级参考文献29

共引文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部