期刊文献+

VOCs罗茨鼓风机故障原因分析与维护对策

Cause Analysis and Maintenance Strategies for VOCs Roots Blower Faults
下载PDF
导出
摘要 本文简单介绍了罗茨鼓风机的结构和工作原理,根据某装置风机在运行中出现的润滑油温度高、电动机跳停、盘车卡涩、轴承卡涩、风机跳停等故障,分析故障的主要原因有维护不到位、管道参数设计不合理、电动机额定参数选型较小、前期设计阶段参与深度不足、设备管理措施滞后等。通过正确监测与管理风机的润滑、对电动机升级改造、按要求管理轴承的全生命周期、增设除渣设施、精细调节工况、优化管理模式等方式进行针对性地改进,显著减少了风机的故障次数,为今后设备的正常运行与维护提供指导。 This article briefly introduces the structure and working principle of Roots blower.Based on the faults that occur during the operation of a certain device's fan,such as high lubricating oil temperature,motor tripping,disc jamming,bearing jamming,and fan tripping,the main reasons for the faults are analyzed to be inadequate maintenance,unreasonable design of pipeline parameters,small selection of motor rated parameters,insufficient participation in the early design stage,and lagging equipment management measures.By correctly monitoring and managing the lubrication of fans,upgrading and renovating motors,managing the entire life cycle of bearings as required,adding dregs removal facilities,finely adjusting operating conditions,and optimizing management modes,targeted improvements have been made,significantly reducing the number of fan failures and providing guidance for the operation and maintenance of equipment in the future.
作者 雍伟峰 Yong Weifeng(Sinopec Hunan Petrochemical Co.,Ltd.,Yueyang 414000,China)
出处 《广东化工》 CAS 2024年第10期211-212,207,共3页 Guangdong Chemical Industry
关键词 罗茨鼓风机 结构 维护 改进 故障次数 roots blower structure maintenance improve failure frequency
  • 相关文献

参考文献2

二级参考文献21

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;