摘要
建立测定水中阿特拉津的液液萃取-气相色谱法,通过设计三因素三水平的正交实验和极差分析优化获得液液萃取条件。从方法的检出限、测定下限、精密度、准确度、标准曲线及实际样品测定结果评价方法的适用性。结果表明,阿特拉津在0.1~1.0mg·L^(-1)浓度范围内线性良好,相关系数为0.9999,回收率为96.1%~99.1%,相对标准偏差为4.3%~6.0%,方法检出限为0.02μg·L^(-1),测定下限为0.08μg·L^(-1)。该方法操作简单、准确度好,适用于测定水中阿特拉津。
A new method was established to detect Atrazine in water by liquid-liquid extraction gas chromatography.A complete orthogonal test with three factors and three levels was designed and then the range analysis was used to optimize the liquid-liquid extraction conditions.The analysis effect of the method was evaluated from the limit of detection,precision,accuracy,standard curve,and the determination results of real samples.The results showed that the linearity of atrazine was good in the range of 0.1~1.0mg·L^(-1),the correlation coefficient was 0.9999.The recoveries were 96.1%~99.1% with relative standard deviation of 4.3%~6.0%.The limit of detection was 0.02μg·L^(-1),and the limit of quantification was 0.08μg·L^(-1).This method is simple to operate and has good accuracy.This method is suitable for the determination of Atrazine in water.
作者
谢璇
杜明月
赵娇娇
葛璇
张水燕
XIE Xuan;DU Ming-yue;ZHAO Jiao-jiao;GE Xuan;ZHANG Shui-yan(Jinan Eco-Environment Monitoring Center of Shandong Province,Jinan 250100,China)
出处
《化学工程师》
CAS
2024年第8期27-29,43,共4页
Chemical Engineer
基金
2023年山东省生态环境污染防治资金项目(2023S92):济南市黄河流域水生态状况评估。
关键词
阿特拉津
液液萃取
气相色谱法
正交实验
Atrazine
liquid-liquid extraction
gas chromatography
orthogonal test