摘要
分析了定电位电解法监测糖厂锅炉烟气中SO_(2)遇到的问题和非分散红外吸收法和紫外差分吸收法的特点,提出对策着力解决监测问题,提高SO_(2)监测数据可靠性。
This article analyzed the problems encountered in monitoring SO_(2) in sugar factory boiler flue gas by constant potential electrolysis,and analyzed the characteristics of non-dispersive infrared absorption method and ultraviolet differential absorption method.The countermeasures were proposed to solve the monitoring problems and improve SO_(2) monitoring data reliability.
作者
寸特升
CUN Te-sheng(Dehong Ecological and Environmental Monitoring Station of DEEY,Dehong Yunnan 678400,China)
出处
《环境科学导刊》
2024年第5期86-90,共5页
Environmental Science Survey
关键词
SO_(2)
定电位电解法
非分散红外吸收法
紫外差分吸收法
问题
对策
SO_(2)
constant potential electrolysis method
non-dispersive infrared absorption method
ultraviolet differential absorption method
problems
countermeasures