期刊文献+

Seismic evaluation of frequency influence and resonant behavior for lead rubber bearing isolated rigid rectangular liquid tanks

下载PDF
导出
摘要 The seismic behavior of a partially filled rigid rectangular liquid tank is investigated under short-and longduration ground motions.A finite element model is developed to analyze the liquid domain by using four-noded quadrilateral elements.The competency of the model is verified with the available results.Parametric studies are conducted for the dynamic parameters of the base-isolated tank,using a lead rubber bearing to evaluate the optimum damping and time period of the isolator.The application of base isolation has reduced the total and impulsive hydrodynamic components of pressure by 80 to 90 percent,and base shear by 15 to 95 percent,depending upon the frequency content and duration of the considered earthquakes.The sloshing amplitude of the base-isolated tank is reduced by 18 to 94 percent for most of the short-duration earthquakes,while it is increased by 17 to 60 percent for the majority of the long-duration earthquakes.Furthermore,resonance studies are carried out through a long-duration harmonic excitation to obtain the dynamic behavior of non-isolated and isolated tanks,using a nonlinear sloshing model.The seismic responses of the base-isolated tank are obtained as higher when the excitation frequency matches the fundamental sloshing frequency rather than the isolator frequency.
出处 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第4期973-994,共22页 地震工程与工程振动(英文刊)
  • 相关文献

参考文献5

二级参考文献69

  • 1Cheung Pakchiu.Seismic performance of cable-sliding friction bearing system for isolated bridges[J].Earthquake Engineering and Engineering Vibration,2012,11(2):173-183. 被引量:7
  • 2Kenneth K. Walsh Makola M. Abdullah.Adaptive base-isolation of civil structures using variable amplification[J].Earthquake Engineering and Engineering Vibration,2006,5(2):223-233. 被引量:3
  • 3Abali E and Uckan E (2009), "Parametric Analysis of Liquid Storage Tanks Base Isolated by Curved Surface Sliding Bearings," Soil Dynamics and Earthquake Engineering, 30(1-2): 21-31.
  • 4API (2009), "Welded Steel Tanks of Oil Storage," N.W., Washington D.C., American Petroleum Institute.
  • 5Bachmann H and Wenk T (2000), "Softening Instead of Strengthening for Seismic Rehabilitation," International Structural Engineering, 10(1): 61-65.
  • 6Boduroglu MH, Timur T and Timur SC (2006), "Evaluation of Seismic Safety of Liquid Storage Tanks and Application of Base Isolation System," Report No. ICTAG 1587/MAK(1021054), OCAK, Ystanbul.
  • 7Chalhoub MS and Kelly JM (1990), "Shake Table Test of Cylindrical Water Tanks in Base-isolated Structures," Journal of Engineering Mechanics, 116(7): 1451-1472.
  • 8Christovasilis IP and Whittaker AS (2008), "Seismic Analysis of Conventional and Isolated LNG Tanks Using Mechanical Analogs," Earthquake Spectra, 24(3): 599-616.
  • 9Constantinou, MC, Tsopelas P, Kasalaniti A and Wolff ED (1999), "Property Modification Factors for Seismic Isolation Bearings," Report No. MCEER 99-0012, Multidisciplinary Center for Earthquake Engineering Research, State University of New York at Buffalo, Buffalo, NY.
  • 10Dunkerley S (1894), "On the Whirling and Vibration of Shafts," Philosophical Transactions of the Royal Society of London, 185: 279-360.

共引文献36