摘要 目的探究肾超声检查联合血流动力学指标对早期糖尿病肾病(DN)的诊断价值。方法回顾性分析2021年2月至2023年11月本院收治的78例DN患者的临床资料,依据不同24 h尿蛋白定量(24 h U-pro)将患者分为DN临床期组(48例,24 h U-pro>0.5 g)和DN早期组(30例,24 h U-pro为0.15~0.50 g);另选取肾功能正常的30例糖尿病(DM)患者设为DM组,比较三组患者的超声肾脏扫描以及血流动力学指标。结果DN临床期组患者的肾脏体积小于DN早期组与DM组,DN早期组患者的肾脏体积小于DM组,差异均有统计学意义(均P<0.05)。DN临床期组患者的肾主动脉Vs_(max)、Vd_(min)均低于DN早期组与DM组,RI高于DN早期组与DM组,DN早期组患者的肾主动脉Vs_(max)、Vd_(min)低于DM组,RI高于DM组,差异均有统计学意义(均P<0.05)。DN临床期组患者的肾窦部动脉Vs_(max)、Vd_(min)低于DN早期组与DM组,RI高于DN早期组与DM组,DN早期组患者的肾窦部动脉Vs_(max)、Vd_(min)均低于DM组,RI高于DM组,差异均有统计学意义(均P<0.05)。DN临床期组患者的肾叶间动脉Vs_(max)、Vd_(min)低于DN早期组与DM组,RI高于DN早期组与DM组,DN早期组患者的肾叶间动脉Vs_(max)、Vd_(min)低于DM组,RI高于DM组,差异均有统计学意义(均P<0.05)。结论超声检查在评定不同阶段DN的肾脏结构和血液流动特性方面具有高度的精确性。此技术能够详细揭示DN患者肾脏损害的程度。在诊断早期DN时,血液流动的测量指标显示出极大的临床应用潜力。 ObjectiveTo explore the diagnostic value of renal ultrasonography combined with hemodynamic indexes in early diabetic nephropathy(DN).MethodsThe clinical data of 78 patients with DN admitted to our hospital from February 2021 to November 2023 were retrospectively analyzed.According to different 24 h urinary protein levels(24 h U-pro),the patients were divided into clinical DN group(48 cases,24 h U-pro>0.5 g)and early DN group(30 cases,24 h U-pro was 0.15-0.5 g),and and 30 DM patients with normal renal function were selected as DM group.The ultrasound renal scan and hemodynamic parameters of the three groups were compared.ResultsThe kidney volume of patients in the DN clinical stage group was significantly lower than that in the early DN group and the DM group,and the kidney volume of patients in the early DN group was significantly lower than that in the DM group(all P<0.05).Vs_(max) and Vd_(min) of renal aorta in the DN clinical stage group were lower than those in the early DN group and DM group,RI was higher than those in the early DN group and DM group,Vs_(max) and Vd_(min) of renal aorta in the early DN group were lower than those in the DM group,RI was higher than those in the DM group,and the differences were statistically significant(all P<0.05).The renal sinus artery Vs_(max) and Vd_(min) of patients in the DN clinical stage group were lower than those in the early DN group and DM group,RI was higher than those in the early DN group and DM group,the renal sinus artery Vs_(max) and Vd_(min) of patients in the early DN group were lower than those in the DM group,and RI was higher than those in the DM group,with statistical significance(all P<0.05).The renal interlobar artery Vs_(max) and Vd_(min) of patients in the DN clinical stage group were lower than those in the early DN group and DM group,RI was higher than those in the early DN group and DM group,the renal interlobar artery Vs_(max) and Vd_(min) of patients in the early DN group were lower than those in the DM group,and RI was higher than those in the DM group,with statistical significance(all P<0.05).ConclusionsUltrasonography is highly accurate in evaluating renal structure and blood flow characteristics in different stages of DN.This technique can reveal the extent of kidney damage in DN patients in detail.The measurement of blood flow shows great potential for clinical application in the diagnosis of early diabetic nephropathy.
作者 高翔 孙爱童 刘洋 周国霞 郎赢 Gao Xiang;Sun Aitong;Liu Yang;Zhou Guoxia;Lang Ying(Department of Ultrasound Medicine,People′s Hospital of Inner Mongolia Autonomous Region,Hohhot 010017,China)
出处 《国际泌尿系统杂志》 2024年第5期912-916,共5页 International Journal of Urology and Nephrology
基金 内蒙古自治区卫生健康科研项目(202201041) 内蒙古自治区人民医院院级项目(YKD2022LH053)。
关键词 糖尿病肾病 超声检查 血流动力学 Diabetic Nephropathies Ultrasonography Hemodynamics
  • 相关文献

参考文献10

二级参考文献53

共引文献272

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部