期刊文献+

骨水泥聚乙烯内衬技术在髋关节翻修术中的应用效果

Application effect of bone cement polyethylene lining technology in revision total hip arthroplasty
下载PDF
导出
摘要 目的分析骨水泥聚乙烯内衬技术在髋关节翻修术中的应用效果。方法回顾性分析2018年1月至2021年1月行髋关节翻修术的72例患者的临床资料,根据手术方法的差异将其分为对照组(n=32)和观察组(n=40)。对照组采用单纯更换聚乙烯内衬,观察组采用骨水泥聚乙烯内衬技术。比较两组的临床效果。结果术后1周以及术后1、3、6、12个月和末次随访,两组的Harris评分均高于术前,视觉模拟量表(VAS)评分均低于术前(P<0.05)。末次随访,观察组的髋臼杯外展角小于对照组(P<0.05)。结论骨水泥聚乙烯技术治疗髋关节翻修能够明显改善患者的髋关节功能,减轻疼痛程度,其效果与单纯更换聚乙烯内衬的效果相当,且该方法的髋臼杯外展变化较小,具有较高的稳定性和安全性。 Objective To analyze the application effect of bone cement polyethylene lining technology in revision total hip arthroplasty.Methods The clinical data of 72 patients who underwent revision total hip arthroplasty from January 2018 to January 2021 were retrospectively analyzed.According to the difference of surgical methods,the patients were divided into control group(n=32)and observation group(n=40).The control group was treated with simple replacement of polyethylene lining,and the observation group was treated with bone cement polyethylene lining technology.The clinical effects of the two groups were compared.Results At 1 week after operation,1,3,6,12 months after operation and at the last follow-up,the Harris scores of the two groups were higher than those before operation,and the Visual Analogue Scale(VAS)scores were lower than those before operation(P<0.05).At the last follow-up,the acetabular cup abduction angle of the observation group was smaller than that of the control group(P<0.05).Conclusion Bone cement polyethylene lining technology in the treatment of revision total hip arthroplasty can significantly improve the patients'hip joint function and reduce the degree of pain.The effect is equivalent to the effect of simple replacement of polyethylene lining,and the acetabular cup abduction change is small,with high stability and safety.
作者 陈会斌 徐华 易朝辉 CHEN Huibin;XU Hua;YI Zhaohui(No.1 Orthopedics Department,Xunyang People's Hospital,Ankang 725700;Joint Surgery Department,the First Hospital of Hanbin District,Ankang 725000;Orthopedics Department,the Hospital ofZhenping County,Ankang 725699,China)
出处 《临床医学研究与实践》 2024年第29期79-82,共4页 Clinical Research and Practice
关键词 骨水泥 聚乙烯内衬 髋关节翻修术 bone cement polyethylene lining revision total hip arthroplasty
  • 相关文献

参考文献12

二级参考文献88

  • 1吴泰相,刘关键,李静.影响系统评价质量的主要因素浅析[J].中国循证医学杂志,2005,5(1):51-58. 被引量:50
  • 2刘建平.非随机研究的系统评价方法(一)[J].中国循证医学,2001,1(4):239-243. 被引量:73
  • 3卫茂玲.Cochrane系统评价在中国的现状与问题[J].中国循证医学杂志,2006,6(2):150-151. 被引量:13
  • 4Adelani MA,Mall NA,Nyazee H,et al.Revision Total Hip Arthroplasty with Retained Acetabular Component.J Bone Joint Surg.2014;96(12):1015-1020.
  • 5Ong KL,Mowat FS,Chan N,et al.Economic burden of revision hip and knee arthroplasty in Medicare enrollees.Clin Orthop Relat Res.2006;446:22-28.
  • 6He C,Feng JM,Yang QM,et al.Results of selective hip arthroplasty revision in isolated acetabular failure.J Surg Res.2010;164(2):228-233.
  • 7Koh KH,Moon YW,Lim SJ,et al.Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty.Arch Orthop Trauma Surg.2011;131(11):1591-1600.
  • 8Talmo CT,Kwon YM,Freiberg AA,et al.Management of polyethylene wear associated with a well-fixed modular cementless shell during revision total hip arthroplasty.J Arthroplasty.2011;26(4):576-581.
  • 9Mauerhan DR,Peindl RD,Coley ER,et al.Cementation of polyethylene liners into well-fixed metal shells at the time of revision total hip arthroplasty.J Arthroplasty.2008;23(6):873-878.
  • 10Della Valle CJ,Mesko NW,Quigley L,et al.Primary total hip arthroplasty with a porous-coated acetabular component.A concise follow-up,at a minimum of twenty years,of previous reports.J Bone Joint Surgery Am.2009;91(5):1130-1135.

共引文献89

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部