摘要 针对尿素装置高压液氨泵在运行中出现振动值缓慢上涨的现象,采用先进的频谱技术判断泵体故障点,解体检查分析故障原因,通过更换转子和主油泵梅花软连接、改进油密封测振环等措施,成功消除了液氨泵振动值高的故障,确保了装置安全稳定的长周期运行。 With regard to the growing of vibration value of high pressure liquid ammonia pump in urea plant,the advanced frequency spectrum technology was used to diagnose the defects on the pump body.Analyzed the failure reason after disassemble and detection,some measures were taken to eliminate the vibration failure successfully,such as changing the rotator and the main oil pump wabbler,modifying the oil seal vibration detection ring,which ensured the safe,stable and long term operation of the plant.
作者 秦荣 谢贵敏 李碧松 Qin Rong;Xie Guimin;Li Bisong(Chongqing Jianfeng Chemical Industry Co.,Ltd.,Chongqing 408017)
出处 《大氮肥》 CAS 2024年第5期328-330,共3页 Large Scale Nitrogenous Fertilizer Industry
关键词 高压液氨泵 振动值高 频谱分析 梅花软连接 油密封测振环 high pressure liquid ammonia pump high vibration value frequency spectrum analysis wabbler oil seal vibration detection ring