期刊文献+

Impact of ultrasound and optical biometry on refractive outcomes of cataract surgery after penetrating keratoplasty in keratoconus 被引量:1

Impact of ultrasound and optical biometry on refractive outcomes of cataract surgery after penetrating keratoplasty in keratoconus
原文传递
导出
摘要 AIM: To analyse the impact of ultrasound and optical intraocular lens(IOL) calculation methods on refractive outcomes of cataract phacoemulsification performed after penetrating keratoplasty(PK) in keratoconus. METHODS: Phacoemulsification cataract surgery was performed on 42 eyes of 34 patients with keratoconus who had previously undergone PK. The IOL power was determined by using both standard and corneal topography-derived keratometry using the SRK/T formula. We used two independent methods-ultrasound biometry(UB) and interferometry [optical biometry(OB)] for IOL calculation. The analysed data from medical records included demographics, medical history, best corrected visual acuity(BCVA) on Snellen charts, technique of IOL calculation and calculation formula and its impact on final refractive result.RESULTS: BCVA ranged from 0.01 to 0.4(mean 0.09±0.19) before surgery and ranged from 0.2 to 0.7(mean 0.38±0.14) at 1 mo and from 0.2 to 1.0(mean 0.56±0.16)(P<0.05) at 3 mo, postoperatively. The refractive aim differed significantly from the refractive outcome in both the UB and OB groups(P<0.05). There was no statistically significant difference in the accuracy of the two biometry methods.CONCLUSION: The refractive aim in keratoconus eyes post-PK is not achieved with either ultrasound or OB. AIM: To analyse the impact of ultrasound and optical intraocular lens(IOL) calculation methods on refractive outcomes of cataract phacoemulsification performed after penetrating keratoplasty(PK) in keratoconus. METHODS: Phacoemulsification cataract surgery was performed on 42 eyes of 34 patients with keratoconus who had previously undergone PK. The IOL power was determined by using both standard and corneal topography-derived keratometry using the SRK/T formula. We used two independent methods-ultrasound biometry(UB) and interferometry [optical biometry(OB)] for IOL calculation. The analysed data from medical records included demographics, medical history, best corrected visual acuity(BCVA) on Snellen charts, technique of IOL calculation and calculation formula and its impact on final refractive result.RESULTS: BCVA ranged from 0.01 to 0.4(mean 0.09±0.19) before surgery and ranged from 0.2 to 0.7(mean 0.38±0.14) at 1 mo and from 0.2 to 1.0(mean 0.56±0.16)(P<0.05) at 3 mo, postoperatively. The refractive aim differed significantly from the refractive outcome in both the UB and OB groups(P<0.05). There was no statistically significant difference in the accuracy of the two biometry methods.CONCLUSION: The refractive aim in keratoconus eyes post-PK is not achieved with either ultrasound or OB.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第6期949-953,共5页 国际眼科杂志(英文版)
关键词 ULTRASOUND BIOMETRY OPTICAL BIOMETRY CATARACT surgery penetrating KERATOPLASTY KERATOCONUS ultrasound biometry optical biometry cataract surgery penetrating keratoplasty keratoconus
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部