摘要 目的 评价在冠脉介入治疗术 (PCI)后应用血管缝合装置Perclose止血的可靠性、安全性及临床应用价值。方法  98例经股动脉冠脉介入治疗术后 ,应用Perclose装置缝合血管止血 ,记录止血时间、下肢制动时间及血管并发症。结果 应用Perclose血管缝合成功率 97% (95 / 98)。止血时间 2 0 1min± 1 2min ,制动时间 4 5h± 1 9h。 1例发生血肿。结论 血管缝合装置Perclose是一种安全、可靠的止血方法 ,术后的止血时间及患肢制动时间明显缩短 。 Objectives To assess the safety and efficacy of a suture device Perclose applied to femoral arterial puncture site after percutaneous coronary intervention (PCI). Methods 98 patients were included, the sheath was removed immediately after PCI, Perclose device was used for hemostasis. The time to achieve hemostasis, the time of ambulance and complications were recorded. Results Perclose device was successfully deployed in 95 patients (97%). 3 cases had underwent failed suture procedure. The time to achieve successful hemostasis was 2 01 min±1 2 min, the time to indentation was 4 5 h±1 9 h, The hematoma occurred in 1 patient. Conclusions The use of Perclose device is a safe and effective method after PCI to achieve immediate hemastasis and shorten bed rest time. It appears be helpful to reduce vascular complications.
出处 《岭南心血管病杂志》 2002年第4期265-267,共3页 South China Journal of Cardiovascular Diseases
关键词 冠脉介入治疗 术后 Perclose血管缝合 止血 Suture device Hemastasis Percutaneous coronary intervention
  • 相关文献

参考文献8

  • 1Muller DM, Shamir KJ, Ellis SG, et al. Peripheral vascular complications after conventional and complex percutaneous transluminal angioplasty. Am J Cardiol, 1992, 69:63 ~ 68
  • 2Ricci MA, Trevisani GT, Pilcher DB, et al. Vascular complications of cardiac catheterization. Am J Surg, 1994, 167:375 ~ 378
  • 3Messina LM, Brothers TE, Wakefield TW, et al. Clinical characteristics and surgical management of vascular complications in patients undergoing catheterization: interventional versus diagnostic procedures. J Vasc Surg, 1991,13:593 ~600
  • 4Ulrich Popma J J, Satler LF, Dilchard AD, et al. Vascular omplication after balloon and new device angioplasty. Circulation, 1993, 88:1569 ~ 1578
  • 5Ernst SMPG, Tjonjoegin RM, Schrader R, et al. Immediate sealing of arterial puncture sites after cardiac catheterization and coronary angioplasty using a biodegradable collagen plug: results of an international registey. J Am Coll Cardiol, 1993,21:851 ~ 855
  • 6Webb JG, Carere RG, Dodek A. Collagen plug hemostatic closure of arterial puncture sites following implantation of coronary stents. Cathet Cardiovasc Diagn, 1993, 30:314 ~316
  • 7Sanbor TA, Gibbs HH, Brinker JA, et al. Amulticenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angingraphy and angioplasty. J Am Coll Cardiol, 1993, 22:1273 ~ 1279
  • 8G erckens U, Cattleaens N, Lampe EG, et al. Management of Arterial Duncture site after catheterization Procedure:Evaluating a Suture-Mediated Closure Device. Am J Cardiol, 1999,83:1658~ 1662

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部