摘要
本文通过静力触探锥尖阻力与标准贯入击数的回归关系,提出了以《建筑抗震设计规范》(GBJ11—89)为基础的饱和砂土液化静力触探判别方法及液化指数的计算方法.
According to the regressive relationship between cone head resistance of static sounding and data of standard penetration test,the article provides a discriminant method of static sounding of saturated sand soil liquefaction and a calculation method of liquefaction index,based on Structure Anti-Seismic Design Code.
出处
《吉林建筑工程学院学报》
CAS
1997年第1期21-26,共6页
Journal of Jilin Architectural and Civil Engineering