摘要 本文通过大型发电机定子主绝缘的联合三因子加速老化试验,研究了主绝缘的介质损耗角正切tanδ的温谱随老化时间的变化规律,提出0 2Un下tanδ T曲线峰值对应的温度Tm可作为表征绝缘老化状态的特征参量,并对其随老化时间的变化规律进行了研究。结果表明,0 2Un下tanδ T曲线峰值对应的温度Tm随老化时间的增加而逐渐升高。 In this paper,the multi\|stress accelerated aging experiment has been conducted on the stator bars of a large generator.The temperature spectra of dielectric dissipation tanδ of stator insulation at different aging time are investigated.It is found that the peak temperature Tm of the tanδT curve under 0.2Un shifts to higher temperature with aging time and can be used to estimate the aging condition of large generator stator insulation.At the same time,the geadient of the peak decreased with aging time and disappeared after final aging cycle.
出处 《电工电能新技术》 CSCD 2003年第1期48-51,共4页 Advanced Technology of Electrical Engineering and Energy
基金 国家自然科学基金重点资助项目(59837260)
关键词 大型发电机 主绝缘 多因子老化 温谱 汽轮发电机 介质损耗 stator insulation multi\|factor aging dielectric dissipation fact
  • 相关文献

参考文献3

二级参考文献5

共引文献6

同被引文献52

  • 1Jeremy C,Wheeler G.Effects of converter pulses on the electrical insulation in low and medium voltage motors[J].IEEE Electrical Insulation Magazine,2005,21(2):22-29.
  • 2Yin Weijun.Failure mechanism of winding insulations in inverter-fed motors[J].IEEE Electrical Insulation Magazine,1997,13(6):18-23.
  • 3Mohsen Farahani,Hossein Borsi,Ernst Gockenbach,et al.Partial discharge and dissipation factor behavior of model insulating systems for high voltage rotating machines under different stresses[J].IEEE Electrical Insulation Magazine,2005,12(5):5-19.
  • 4S R Campbell,G C Stone.Examples of stator winding partial discharge due to inverter drives[A].Conference Record of IEEE International Symposium on Electrical Insulation[C].Anaheim,CA,USA,2000.231-234.
  • 5Weijun Yi,Keith Bultemeier,Don Barta,et al.Dielectric integrity of magnet wire insulations under multi-tress[A].Proc.of EEICEMCW[C].1995.257-261.
  • 6F Guastavino,G Coletti,A Dardano,et al.Life tests on twisted pairs subjected to PWM-like voltages[A].2004 International Conference on Solid Dielectrics[C].Toulouse,France,2004.
  • 7Fabiani D,Montanari G C,Cavallini A,et al.Relation between space charge accumulation and partial discharge activity in enameled wires under PWM-like voltage waveforms[J].IEEE Trans.on Dielectrics and Electrical Insulation,2004,11(3):393-405.
  • 8Yue B, Chen X L, Cheng Y H, et al. Diagnosis of stator winding insu- lation of large generator based on partial discharge mensurement[J]. IEEE Transactions on Energy Conversion, 2006, 21 (2): 387-395.
  • 9Hao Y P, Wang G L, Jia Z D, et al, Application of ultrasonic pulse-echo method to insulation condition diagnosis for large genera- tors[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2005, 12(1): 104-113.
  • 10Hao Y P, Xie H K, Wang G L, et al. Assessment of insulation condi- tion of generator stator bars based on velocity of ultrasonic waves[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2003, 10(3): 539-547.