期刊文献+

低温工况下结霜对翅片管蒸发器性能影响的实验研究 被引量:6

Effect on the Performance of Finned-tube Evaporator of Frost in Low Temperature Conditions
下载PDF
导出
摘要 翅片管蒸发器的结霜将增加空气压降 ,增大传热热阻 ,从而直接影响到蒸发器的效率及空气侧平均换热系数。文中就低温工况下结霜对蒸发器性能的影响进行了测试研究 。 Frost of finned-tube evaporator will increase air pressure drop and heat transfer resistance. It affects the efficiency of the evaporator and the average heat transfer coefficient of air part. The effects on the performance of finned-tube evaporator of frost have been conducted under low temperature conditions in this paper. The results provide an important basis for the design and application of the finned-tube evaporator.
作者 刘凤珍 于阳
出处 《低温与超导》 CAS CSCD 北大核心 2003年第1期27-30,共4页 Cryogenics and Superconductivity
关键词 低温工况 结霜 翅片管蒸发器 性能 实验研究 制冷设备 技术参数 设计 Frost, Finned-tube evaporator, Performance
  • 相关文献

参考文献4

  • 1Rite R W, The effect of frost accumulation on the performance of domestic refrigerator freezer finned-tube evaporator coils, ASHRAE, 1991, 97, part Ⅱ :428-437
  • 2Sekhar N Kondepudi, Dennis L O'Neal, Performance of finned tube heat exchangers under frosting conditions: Ⅰ Simulation model. Int. J. Refrigeration, 1993,16(3) : 175-180
  • 3Sekhar N Kondepudi, Dennis L O'Neal, Performance of finned tube heat exchangers under frosting conditions: Ⅱ comparison of experimental data with simulative data, Int. J. Refrigeration, 1993, 16(3):181-184
  • 4刘凤珍,陈焕新,连添达.影响翅片管换热器结霜因素的研究[J].低温工程,2000(4):45-48. 被引量:20

二级参考文献2

  • 1刘凤珍.低温环境下翅片管换热器的结霜性能和除霜研究:(博士学位论文)[M].天津:天津商学院,1999.4.
  • 2刘凤珍,硕士论文,1999年

共引文献19

同被引文献51

引证文献6

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部