微(差)压变送器的校验及其测量不确定度的评定 被引量:1

Inspection Method of Micro-Pressure(Differential Pressure) Transmitters and Evaluation of Measurement Uncertainty
下载PDF
导出
摘要 介绍以补偿式微压计作为压力标准器来校验高精度的微 (差 )压变送器的一种新方法 ,并依据JJF10 5 9- 1999《测量不确定度评定与表示》 ,对其校验系统的测量不确定度进行了分析 ,并举例说明不确定度评定方法。理论和实践均证明该方法经济实用 。 A new method of inspecting the higher precision micro pressure(differential pressure) transmitters with compensated micro manometer as pressure standards is presented.According to JJF1059-1999《Evaluation and Expression of Uncertainty in Measurement》,the uncertainty of pressure transmitter inspection device is analyzed and some examples are given to illustrate the evaluation procedures.It is proved to be economical and practicable and meets the need of inspecting the higher precision of micro pressure transmitter.
出处 《电力科学与工程》 2002年第4期62-64,共3页 Electric Power Science and Engineering
关键词 微(差)压变送器 校验 测量不确定度 评定 压力标准器 micro pressure(differential pressure) transmitters compensated micro manometer inspection measurement uncertainty
  • 相关文献

参考文献5

共引文献9

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...