摘要
应用全自动固相萃取-气相色谱法测定水中多氯联苯6个Aroclor系列的总量。以特征'指纹峰'为定性依据,用外标法定量。优化的固相萃取条件为:1固相萃取柱为Bond Elut C18柱;2水样体积1.0L;3水样流量10mL·min-1;4洗脱剂为15mL二氯甲烷和15mL乙酸乙酯。用DB-5MS柱分离,电子捕获检测器检测。各多氯联苯的线性范围均为7.0~140.0μg·L-1,检出限均为0.7μg·L-1。以空白样品为基体进行加标回收试验,所得回收率在70.1%~90.0%之间,测定值的相对标准偏差(n=6)在4.3%~6.6%之间。
GC was applied to the determination of total PCBs in water with automatic solid phase extraction.Characterized'fingerprint peaks'were used for qualitative anaylsis while the external standard was used for quantitative analysis.The optimized conditions of solid phase extraction found were as follows:1column of solid phase extraction:Bond Elut C18column;2 volume of water sample:1.0L;3flow of water sample:10mL·min-1;4elution solvents:15mL methylene chloride and 15 mL of ethyl acetate.The analytes were separated on DB-5MS column and detected by ECD.Linearity ranges of PCBs were found same between 7.0μg·L-1 and140.0μg·L-1 with detection limits of 0.7μg·L-1.On the base of blank sample,test for recovery was made by standard addition method;values of recovery found were in the range of 70.1%-90.0%,with RSD′s(n=6)in the range of 4.3%-6.6%.
出处
《理化检验(化学分册)》
CAS
CSCD
北大核心
2014年第9期1135-1138,共4页
Physical Testing and Chemical Analysis(Part B:Chemical Analysis)