期刊文献+

国产抗-HIV ELISA诊断试剂质量提高的血清学证实 被引量:10

Serologic evidence of quality improvement of domestic HIV-antibody detecting ELISA kits
下载PDF
导出
摘要 目的 了解国产抗 HIVELISA诊断试剂质量提高情况 ,保证检测结果的准确性。方法 使用卫生部艾滋病预防与控制中心艾滋病参比实验室的试剂质量考核血清盘 ,对 3种国产抗 HIVELISA试剂质量考核 ,并对结果比较分析。结果  2 0 0 1年生产的抗 HIVELISA诊断试剂敏感性比 1998、1999年的试剂明显提高 ,阳性漏检率明显减少。结论 国产抗 HIVELISA诊断试剂质量在不断提高 。 Objective To investigate the quality of current domestic HIV antibody detecting kits and to assure the credibility of experimental results.Methods The sensitivity and specificity of three kinds of domestic HIV antibody detection ELISA kits made in three different years were evaluated and compared by testing the serum panel from National AIDS Reference Laboratory.Results The sensitivity of kits produced by three domestic manufacturers in 2001 is significantly better than the kits produced in 1998 and 1999.The false negative rates were apparently decreasing.Conclusions The quality of domestic HIV antibody detecting kits has been improving steadily.The sensitivity of double antigen sandwich ELISA assay is apparently better than the indirect ELISA assay.
出处 《中国输血杂志》 CAS CSCD 2003年第2期81-83,共3页 Chinese Journal of Blood Transfusion
关键词 抗-HIV ELISA 诊断 试剂 质量 血清学 艾滋病 预防 HIV antibody ELISA kit evaluation
  • 相关文献

参考文献10

  • 1卫生部.全国艾滋病检测工作规范[M].,1997..
  • 2Nkengasong J, Van Kerekhoven I, Vercauteren G, Altemative confirmatory strategy for anti-HIV antibody detection, j Virol Methods. 1992,38(2) :263.
  • 3Ittiravivongs A, Likanonsakul S, Limpakarnjanarat K, et al. Evaluation of a confirmatory HIV testing strategy in Thailand not using western blot. J Aequir Immune Defie Syndr Hum Retrovirol, 1996,13(3) :296.
  • 4Matter L, Germann D. Detection of human immunodefieieney virus(HIV) type 1 antibodies by a new automated microparticle enzyme immunoassay for HIV types 1 and 2. J Clin. Microhiol, 1995,33 :2338.
  • 5Weber B, Behrens N, Doerr HW. Detection of human immunodeficiency virus type 1 and type 2 antibodies by a new automated microparticle immunoassay, J Virol. Methods, 1997,63 : 137.
  • 6Weber B,Doerr HW. Evaluation of the automated VIDAS system for the detection of anti-HIV-1 and anti-HIV-2 antibodies, J Virol.Methods, 1993,42 : 63.
  • 7Weber BG, Hess R. Koberstein HR, and Doerr HW. Evaluation of the automated"Enzymun-Test Anti HIV 1 + 2"and"Enzymun-Test Anti-HIV1/2 selective" for the combined detection and differentiation of anti-HIV-1 and anti-HIV-2 antibodies J Virol. Methods,1993,44:251.
  • 8Weber B, Hess G, Enzensberger R, et al. Muhicenter evaluation of the novel ABN western blot (immunoblot) system in comparison with an enzyme-linked immunosorbent assay and a different western blot. J. Clin. Microbiol, 1992,30 : 691.
  • 9Weber B. Multicenter evaluation of the new automated Ermymun-Test Anti-HIV 1 + 2 + subtyp O J Clin Microbiol, 1998, 36(2):580.
  • 10Zaaijer HL,Exel-Oehlers VP,Kraaijeveld T, et al. Early detection of antibodies to HIV-1 by third-generatioxn assays. Lancet, 1992,26,340(8822) :770.