简要介绍了胜利发电厂一号汽轮机通流部分改造的技术方案,并通过比较改造前后的热力试验结果,分析了技术改造取得的经济效益。
The flow passage transformation technique scheme of NO.1 steam turbine in Shengli Power Plant was introduced briefly. A comparison of thermodynamic test result between before and after transformation was made and the economic benefit has been gained after transformation.