期刊文献+

钠型蒙脱石修饰碳糊电极测定微量的铜离子 被引量:5

Voltammetric Determination of Cu^(2+) Using Sodium Montmorillonite Modified Carbon Paste Electrode
下载PDF
导出
摘要 报道了一种高灵敏度 ,快速测定水体中铜离子的化学修饰碳糊电极。详细研究了测定铜离子的条件。该修饰电极测定铜离子的线性范围为 1× 1 0 - 9~ 1 .5× 1 0 - 7mol/L ,富集 6min后的检出限为 3× 1 0 - 10 mol/L。该方法简便、快速、灵敏。用该修饰电极测定了实际水样中的铜离子 ,平均回收率为 1 0 0 .8%。 A sodium montmorillonite (SWy 2) modified carbon paste electrode was examined for the determination of trace levels of Cu 2+ . Due to its strong cation exchange and adsorptive characteristics, SWy 2 greatly imprioved the sensitivity of determination of Cu 2+ . Cu 2+ was preconcentrated and reduced on the modified electrode surface at -0.70 V, and then stripped from the electrode surface during the positive potential sweep. The determination parameters, such as supporting electrolyte, pH value, the amount of SWy 2, accumulation potential and time were optimized. The peak current was linear with the concentration over the range from 1×10 -9 mol/L to 1.5×10 -7 mol/L. The detection limit (signal to noise=3) was 3×10 -10 mol/L after 6 min accumulation. Using the SWy 2 modified carbon paste electrode, Cu 2+ in the water samples was detected with the average recovery of 100.8%.
出处 《分析科学学报》 CAS CSCD 北大核心 2003年第3期261-263,共3页 Journal of Analytical Science
基金 湖北省教育厅重点项目 ( 2 0 0 2 0 0 80 1 0 )
关键词 钠型蒙脱石 修饰电极 碳糊电极 测定 微量分析 铜离子 溶出伏安法 Sodium montmorillonite Cu 2+ Modified carbon paste electrode Stripping voltammetry
  • 相关文献

参考文献1

二级参考文献2

  • 1Tasi Y C,Electroanalysis,2001年,13卷,1期,7页
  • 2Chen Z L,Electroanalysis,1992年,11卷,3期,964页

共引文献12

同被引文献58

  • 1何为,唐先忠,王守绪,王磊.线性扫描伏安法与循环伏安法实验技术[J].实验科学与技术,2005,3(z1):126-128. 被引量:19
  • 2姚朝英,杜青.原子吸收光谱法测定水生生物体内铜、锌、镍、铬、铅、镉[J].化学分析计量,2006,15(3):36-37. 被引量:17
  • 3魏小平,林剑平,李建平.掺杂2,9-二甲基-4,7-二苯基-1,10-邻二氮菲的石蜡碳糊铜离子选择性电极的研究[J].分析试验室,2006,25(7):90-93. 被引量:12
  • 4谢洛声.离子选择电极分析技术[M].北京:化学工业出版社,1985:240-248.
  • 5Ren K. A liquid-state copper(Ⅱ) ion-selective electrode containing a complex of Cu(Ⅱ) with salicylaniline[J].Talanta, 1989, 36 (7):767-771.
  • 6Firooz A R, Mazloum M, Safari J, et al. Coated wire copper(Ⅱ)-selective electrode based on phenylglyoxalmonoxime ionophore[J]. Anal. Bioanal. Chem. , 2002, 372:718- 722.
  • 7Jain A K, Singh P K, Jain S, et al. Copper(Ⅱ) ion selective electrode based on a newly synthesized Sehiff- base chelate[J]. Transition Met. Chem. , 2008, 33: 243- 249.
  • 8Mahajan R K, Sood P. Novel copper(Ⅱ)selective electrode based on 2, 2'-5', 2"- terthiophene in PVC matrix[J]. Int. J. Electrochem. Sci., 2007, 2: 832- 847.
  • 9国家环境保护总局《水和废水监测分析方法》编委会.水和废水监测分析方法:第三版[M].北京:中国环境科学出版社,2002:137~139.
  • 10K.C. Honeychurch, J. P, Hart, D. C, Cowell. Voltammetric studies of lead at a 1 - (2 - pyridylazo) - 2 - naphthol modified screen- printed carbon electrode and its trace determination in water by stripping voltammetry [ J ]. Anal. Chim. Acta. , 2001, 431 : 89.

引证文献5

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部