期刊文献+

Orthogonality of inductosyn angle-measuring system error and error-separating technology 被引量:1

Orthogonality of inductosyn angle-measuring system error and error-separating technology
下载PDF
导出
摘要 Round inductosyn is widely used in inertial navigation test equipment, and its accuracy has significant effect on the general accuracy of the equipment. Four main errors of round inductosyn,i.e. the first-order long-period (360°) harmonic error, the second-order long-period harmonic error, the first-order short-period harmonic error and the second-order short-period harmonic error, are described, and the orthogonality of these four kinds of errors is studied. An error separating technology is proposed to separate these four kinds of errors, and in the process of separating the short-period harmonic errors, the arrangement in the order of decimal part of the angle pitch number can be omitted. The effectiveness of the technology proposed is proved through measuring and adjusting the angular errors. Round inductosyn is widely used in inertial navigation test equipment, and its accuracy has significant effect on the general accuracy of the equipment. Four main errors of round inductosyn,i.e. the first-order long-period (360°) harmonic error, the second-order long-period harmonic error, the first-order short-period harmonic error and the second-order short-period harmonic error, are described, and the orthogonality of these four kinds of errors is studied. An error separating technology is proposed to separate these four kinds of errors, and in the process of separating the short-period harmonic errors, the arrangement in the order of decimal part of the angle pitch number can be omitted. The effectiveness of the technology proposed is proved through measuring and adjusting the angular errors.
出处 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2003年第4期376-379,共4页 哈尔滨工业大学学报(英文版)
关键词 INDUCTOSYN angle measurement error separation ORTHOGONALITY 正交性 感应式传感器 角测量系统 错误分离技术
  • 相关文献

同被引文献7

  • 1齐凤梅,石治国.圆感应同步器安装误差修正方法研究[J].光学技术,2006,32(z1):445-447. 被引量:4
  • 2任顺清,伊国兴,曾庆双,王常虹.小范围回转轴系感应同步器测角系统的误差分离技术[J].电机与控制学报,2005,9(2):183-186. 被引量:8
  • 3REN Shunqing,CHEN Xijun,et al.Integrated error model and error checking & separating technology for round inductosyn angletmeasuring system[C]//Proceedings of the 3rd International Symposium on Instrumentation Science and Technology,August 18-22,2004,Xi'an China.2004:252-257.
  • 4WANG Zhenhuan,CHEN Xijun,LI Ren.Inductosyn angle measuring system error based on AD2S80 resolver-to-digital converter[C]//Fifth International Symposium on Instrumentation Science and Technology,September 15-18,2009,Shenyang,China.2009:1-7.
  • 5TAN K K,LEE T H,DOU H F,et al.Precision Motion Control-design and Iimplementation[M].Great Britain:Springer-verlag London Limited,2001.
  • 6陆永平 芩文远.感应同步器及其系统[M].北京:国防工业出版社,1982..
  • 7孙力,杨贵杰,孙立志.跟踪鉴幅型感应同步器测角系统误差分析[J].电机与控制学报,1999,3(3):181-183. 被引量:6

引证文献1

二级引证文献7