期刊文献+

血清酶测定结果可溯源性研究 被引量:23

Study on the traceability of the serum enzyme assays
原文传递
导出
摘要 目的 通过对酶标准品的测定 ,探讨血清酶测定结果的可溯源性。方法 向参加研究的实验室 (50家 )各发放酶校准品 1支 ,各实验室用常规方法测定校准品 ,记录检验结果 ;计算校准品测定结果总体均值与标示值间的偏倚。结果 丙氨酸氨基转移酶 (ALT)、天门冬氨酸氨基转移酶(AST)、肌酸激酶 (CK)和乳酸脱氢酶 (LD)的测定结果均值与标准品标示值的相对偏差≤± 10 % ,分别为 6 3 % ,5 5% ,-5 9%和 -5 0 % ;碱性磷酸酶 (ALP)的实验室检测结果与标准品标示值间的相对偏倚为 -3 6 6% ,淀粉酶测定结果的实验室间CV为 2 9 2 %。 Objective Study on the traceability of serum enzyme ass ays by testing enzyme reference material in clinical laboratories. Methods 50 laboratories were involved in this survey. One enzyme reference material was send to each participate lab. The reference material was tested by use of routine method and the results were recorded. All lab data were processed with computer. Results Compare with the target values, the bias of alanine aminotransferase (ALT), aspartate aminotransferase (AST), creatine kinase (CK) and lactate dehydrogenase (LD) assays were 6 3%, 5 5%, -5 9% and -5 0% respectively, the bias of alkaline phosphatase (ALP) assays was -36 6. The inter laboratory coefficient variation of the amylase assay was 29 2%. Conclusions The results of enzyme assay in clinical laboratories could be traced to the international reference material.
出处 《中华检验医学杂志》 CAS CSCD 北大核心 2003年第12期761-763,共3页 Chinese Journal of Laboratory Medicine
  • 相关文献

参考文献1

  • 1.中华人民共和国国家标准.检测和校准实验室能力的通用要求[M].北京:中国标准出版社,2001.1-18.

同被引文献107

引证文献23

二级引证文献179

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部