期刊文献+

大面积玻璃RPC模型与性能测试 被引量:2

Performance Test of a Large Area Glass RPC
原文传递
导出
摘要 介绍了可用于粒子探测的大面积玻璃高阻板探测器RPC(ResistivePlateChamber) .使用两块间隔 2mm的普通浮法玻璃作为电极 ,其中充入流动的混合气体 (氩气 +异丁烷 +F134A) ,工作高压约 96 0 0V ;性能测试结果 ,其单室效率可达 97% ,时间分辨可达到 1.8ns . A RPC (resistive plate chamber) prototype made with domestic glass is tested, which is suitable for large area particle detection. The constituent elements are two parallel glass plates with 2mm gas gap. A gas mixture of Argon, Iso-butane and F134A is utilized. Test results show that the chamber efficiency is 97% and time resolution is 1.8ns at an operating voltage 9600V, it has a relatively lower single rates than a normal bakelite chamber. Except for the dead regions caused by the spacers and frame, the efficiencies from different strips in the same readout plate show good consistency. The technological design for mass production for this glass RPC is under investigation.
出处 《高能物理与核物理》 CSCD 北大核心 2004年第1期78-81,共4页 High Energy Physics and Nuclear Physics
基金 中国科学院知识创新项目资助~~
  • 相关文献

参考文献9

  • 1Santonico R, Cardarelli R. Nucl. Instr. and Meth., 1981,187:377-380
  • 2Santonico R, Nucl. Instr. and Meth., 2000,A456:1-5
  • 3LU Hong, SHEN Pei-Ruo, HE Hui-Hai et al. HEP & NP, 1999, 23(5):417-424(in Chinese)(卢红,沈培若,何会海等. 高能物理与核物理,1999,23(5):417-424)
  • 4Bacci C, BAO K Z, Barone F et al. Nucl. Instr. and Meth., 2000,A443:342-350
  • 5Bencivenni G, Gustavino C, Menghetti H et al. Nucl. Instr. and Meth., 2001, A461:319-321
  • 6HUANG Sheng-Li, LI Cheng, XU Zi-Zong et al. HEP & NP, 2003, 27(2):154-157(in Chinese)(黄胜利,李澄,许咨宗等. 高能物理与核物理,2003, 27(2):154-157)
  • 7HAN Hong-Guang, TONG Guo-Liang, OUYANG Qun et al. Nuclear Electronics & Detection Technology,2001, 21(2):142-144(in Chinese)(韩红光,童国梁,欧阳群等. 核电子学与探测器技术,2001,21(2):142-144)
  • 8Carboni G, Collazuol G, Capua S De. Nucl. Instr. and Meth., 2003,A498:135-142
  • 9Adinolfi M, Carboni G, Messi R et al. Nucl. Instr. and Meth., 2000,A456:95-98

同被引文献11

  • 1关梦云,杨长根,孟祥承.RPC读出条的阻抗匹配[J].高能物理与核物理,2004,28(11):1176-1179. 被引量:1
  • 2SANTONICO R. A scientific introduction RPC: Where we are and where we are going[J]. Nucl Instrum Methods, 2000, A456: 1-5.
  • 3SCHUTTAUF A, HILDENBRAND K D, CIOBANU M, et al. Performance of the multistrip- MRPCs for FOPI[J]. Nuclear Physics, 2006, B158(Suppl. ) : 52-55.
  • 4R. Santonico and R. CardareUi. Development of re- sistive plate counters [ J ]. Nuclear Instruments andMethods in Physics Research, 1981, 187(2 -3) :377 - 380.
  • 5S. Biswas, S. Bhattacharya, et al. Development of bakelite based resistive plate chambers [ EB ]. http :// arxiv, org/pdf/0802.2766vl, pdf.
  • 6S. Park, S. H. Ahn,et al. Production of gas gaps for the Forward RPCs of the CMS experiment [ J ]. Nu- clear Instruments and Methods in Physics Research A, 2005, 550(3) :551 -558.
  • 7宁哲.大亚湾实验阻性板室探测器的研制和离线刻度[M].109-120.
  • 8Bo Xie, Yi Wang, et al. A new type of RPC for the VETO of JUNO [ J ]. Journal of Instrumentation, 2014,9(10) C10005.
  • 9Oluwaseun Amoda. Design of Readout System for an Resistive Plate Chamber [ EB ]. http://sist, fnal. gov/archive/2002/papers/Amoda, pdf, 2010,30 ( 3 ) : 367 - 369.
  • 10李宪优,魏学荣,于丽娟,王玲.利用示波器精确测量传输线延迟时间[J].核电子学与探测技术,2010,30(3):367-369. 被引量:2