期刊文献+

三维有限元分析基底冠厚度对金属烤瓷冠应力的影响 被引量:3

Effect of three dimensional finite element analysis of thicknesss of metal base on stress of porcelain fused to metal crown
下载PDF
导出
摘要 目的:分析下颌第一磨牙金属烤瓷冠受载时的应力状况。当临床备牙量一定时(咬合面冠厚2.0mm),研究不同基底冠厚度(0.2,0.4,0.6,0.8mm)对基底冠和瓷层应力状况的影响,为金属烤瓷冠的临床应用提供依据。方法:采用三维有限元分析方法。结果:随着基底冠厚度从0.2mm增大到0.8mm,基底冠和瓷上的压应力峰值与Mises应力峰值有增大的趋势,拉应力峰值则呈降低的趋势。但是,当基底冠厚度为0.2mm时,拉应力峰值远远大于基底冠厚度为0.4,0.6,0.8mm时的拉应力峰值,而后3种厚度基底冠之间的拉应力峰值变化不明显。结论:临床制备烤瓷牙时,选择0.4mm厚度的基底冠较为合理。 AIM:To analyze the stress distribution of the porcelain fused to metal(PFM) crowns of the mandibular first molar under the force,and to study the effects of different thickness of metal base(0.2,0.4,0.6 and 0.8 mm) on the metal base and the porcelain layers when the overall occlusal thickness was maintained(2.0 mm) so as to provide evidence for the clinical application of the PFM crown. METHODS:Three dimension finite element analysis was adopted. RESULTS:The peak values of compressive stress and the Mises stress were increased as the thickness of metal crown was increased from 0.2 mm to 0.8 mm,while the peak value of tensile stress was decreased. The peak value of tensile stress in the PFM crown 0.2 mm in metal base thickness was much higher than the value in the PFM crown 0.4,0.6 and 0.8 mm in metal base thickness. The peak value of tensile stress in the PFM crown 0.4,0.6 and 0.8 mm in metal base thickness had no obvious difference. CONCLUSION:The reasonable thickness of base metal should be 0.4 mm when PFM crown is applied clinically.
出处 《中国临床康复》 CAS CSCD 2004年第5期876-877,共2页 Chinese Journal of Clinical Rehabilitation
  • 相关文献

参考文献6

二级参考文献21

  • 1万乾炳,杜传诗.金瓷修复体瓷折裂的临床修补[J].国外医学(口腔医学分册),1993,20(4):208-211. 被引量:3
  • 2刘雷,沈根标.胸腰椎损伤的三维有限元模型的应力分析[J].中华创伤杂志,1995,11(6):343-344. 被引量:13
  • 3廉云敏 高桥重雄.金属烤瓷冠强度的实验研究[J].中华口腔医学杂志,1999,34(1):39-39.
  • 4郭世绂.临床骨科解剖学(第6版)[M].天津:天津科学技术出版社,1997.148-149.
  • 5孟和 颐志华.骨科生物力学[M].北京:人民卫生出版社,1989.379.
  • 6桑田正博 史书俊(译).金属烤瓷修复体的理论与实践[M].天津:天津科学技术出版社,1984.5.
  • 7谢明 刘逢光.腰椎间盘突出症的生物力学和功能评定[J].现代康复,2001,5(1):61-61.
  • 8何惠明 施长溪 等.铸钛表面多层结构层对钛瓷结合的影响[J].中华口腔医学杂志,1998,33(4):216-216.
  • 9CLAES LE,HEIGELE CA,NEIDLINGER WC,et al.Effects of mechanical factors on the fracture healing process[J].Clin Orthop,1998,355:132-147.
  • 10TANNE K,TANAKA E,SAKUDA M.Stress distribution in the TMJ during clenching in patients with vertical discrepancies of the craniofacial complex[J].J Orofacial Pain, 1995,9:153-155.

共引文献74

同被引文献53

  • 1翟丽云,赵玉珍,王少萍,杨月华.金瓷冠桥失败原因分析[J].华西口腔医学杂志,2005,23(3):231-232. 被引量:10
  • 2张娜,赵守亮,王胜朝,怡力,唐荣银.三种根管预备方法对根部牙体组织应力分布影响的三维有限元分析[J].牙体牙髓牙周病学杂志,2007,17(7):390-393. 被引量:17
  • 3Shirakura A,Lee H,Geminiani A,et al.The influence of veneering porcelain thickness of all-ceramic and metal ceramic crowns on failure resistance after cyclic loading.J Prosthet Dent,2009,101(2):119-127.
  • 4Ulusoy M,Toksavul S.Fracture resistance of five different metal framework designs for metal-ceramic restorations.Int J Prosthodont,2002,15(6):571-574.
  • 5Rosenstiel SF,Land MF,Fujimoto J.Contemporary Fixed Prosthodontics.3rd Ed.,Mosby,USA,2001,488-512.
  • 6Masaka N.Casting accuracy of one-piece cast fixed bridges.Shikwa Gakuho,1970,70(6):725-758.
  • 7Yang HS,Lang LA,Molina A,et al.The effects of dowel design and load direction on dowel-and-core restorations.J Prosthet Dent,2001,85(6):558-567.
  • 8Wang R,Li X,Yang J,et al.Influences of metal frame design on the mechanical strength of posterior porcelain fused to metal crown.Matsumoto Shigaku,2007,33(3):299-312.
  • 9Kojima Y,Yamamoto M,Murakami H,et al.Stress analysis of an all ceramic crown on lower second molar.J Dent Mater,2001,20(3):200-208.
  • 10Yamamoto M,Murakami H,Kojima Y,et al.Stress analysis of molar all-ceramics crown using the three-dimensional finite element method.J Jpn Prosthodont Soc,2001,45(5):622-631.

引证文献3