期刊文献+

基于重复控制的SPWM逆变电源死区效应补偿技术 被引量:38

A Compensation Strategy for Dead-time Effect of SPWM Inverters Based on Repetitive Control
下载PDF
导出
摘要 在SPWM逆变器中,为防止同一桥臂的上下管直通现象,必须注入一定的死区时间,死区会导致逆变器的输出波形畸变,即死区效应。在分析了死区时间对单相SPWM逆变器输出波形特性的影响的基础上,提出了一种基于重复控制的死区补偿控制策略,该控制方法可有效地改善输出电压的波形畸变,并在一台单相400Hz、5.5kW装置上进行了详细的实验验证,实验结果表明了该补偿策略的有效性和实用性。 A few microseconds dead-time must be inserted into the switching signals of SPWM inverters to prevent the short circuit. This can cause the dead-time effect of the output voltage distortion. The influence of dead-time on output voltage in single-phase SPWM inverters is analyzed in detail. A novel dead-time compensation strategy, which can provide excellent inverter output voltage distortion correction based on repetitive control, is also proposed. The experimental results on a 400Hz 5.5kW prototype of inverter are presented to demonstrate the practicability and validity of the control strategy.
出处 《电工技术学报》 EI CSCD 北大核心 2004年第2期52-57,63,共7页 Transactions of China Electrotechnical Society
基金 国家自然科学基金资助项目(50007004)。
关键词 正弦脉宽调制 逆变器 死区 重复控制 补偿 SPWM, inverter, dead-time, repetitive control, compensation
  • 相关文献

参考文献12

  • 1[1]Evans P D,Close P R. Harmonic distortion in PWM inverter output waveforms. IEE Proc. B, 1987,134(4): 224~232
  • 2[2]Yoshihiro Murai, Tomofumi Watanabe, Harumitu Iwasaki. Waveform distortion and correction circuit for PWM inverters with switching lag-times. IEEE Trans. on Ind. Applicat., 1987, 23(5): 881~886
  • 3[3]Leggate D, Kerkman R J. Pulse-based dead-time compensator for PWM voltage inverters. IEEE Transactions on Industrial Electronics, 1997, 44(2): 191~197
  • 4[4]Dodson R C, Evans P D, Tabatabaei Yazdi H,et al. Compensation for dead time degradation of PWM inverter waveforms. IEE Proc. B, 1990, 137(2): 73~81
  • 5[5]Sukegawa T, Kamiyama K, et al. Fully digital vector- controlled PWM VSI-fed AC drives with an inverter dead-time compensation strategy. IEEE Transactions on Industry Applications, 1991, 27(3): 552~559
  • 6[6]Seung-Gi Jeong, Min-Ho Park. The analysis and compensation of dead-time effects in PWM inverters. IEEE Transactions on Industrial Electronic, 1991,38(2): 108~114
  • 7[7]Jong-Woo Choi, Seung-Ki Sul. Inverter output voltage synthesis using novel dead time compensation. IEEE Trans. on Power. Electron., 1996, 11(2): 221~227
  • 8[8]Takashi Sukegawa, Kenzo Kamiyama, Katsuhiro Mizuno, et al. Fully digital, vector- controlled PWM VSI-fed AC drives with an inverter dead-time compensation strategy. IEEE Trans. on IA, 1991, 27(3): 552~558
  • 9[9]Alfredo R Munoz , Thomas A Lipo. On-line dead-time compensation technique for open-loop PWM-VSI drives. IEEE Trans. on Power Electron., 1999, 14(4): 683~689
  • 10[10]Jong-Woo Choi, Seung-Ki Sul. A new compensation strategy reducing voltage/current distortion in PWM VSI systems operating with low output voltages. IEEE Trans. on Ind. Applicat., 1995, 31(5): 1001~1008

同被引文献328